Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Dec;94(6):1312-7.
doi: 10.1160/TH05-06-0426.

D-dimer, P-selectin, and microparticles: novel markers to predict deep venous thrombosis. A pilot study

Affiliations
Comparative Study

D-dimer, P-selectin, and microparticles: novel markers to predict deep venous thrombosis. A pilot study

John E Rectenwald et al. Thromb Haemost. 2005 Dec.

Abstract

Current plasma markers for diagnosis of deep venous thrombosis (DVT) allow for exclusion of the diagnosis, but lack adequate specificity to establish the diagnosis. Thus, a prospective study was performed to determine the sensitivity and specificity of plasma assays for D-dimer, soluble P-selectin (P-selectin), and total microparticles in patients with documented DVT by duplex ultrasound. Three groups of individuals were examined: 30 normals; 22 positive for DVT on duplex ultrasound (Group 2); and 21 symptomatic, but negative on duplex ultrasound for DVT (Group 3). Group 1 individuals had D-dimer values of 1.53 +/- 0.12 mg/l and P-selectin values of 0.34 +/- 0.05 ng/mg total protein. Group 2 vs. Group 3 individuals had D-dimer values of 7.57 +/- 2.03 vs. 3.19 +/- 0.79 mg/l, p = 0.02; P-selectin values of 0.98 +/- 0.11 vs. 0.55 +/- 0.08 ng/mg total protein, p < 0.01; and micro-particle values of 129 +/- 17% vs. 99 +/- 12% of control, p = ns. Using a logistic regression model with dichotomous variables, we determined a sensitivity of 73%, specificity of 81%, and accuracy of 77% when combining D-dimer, soluble P-selectin, and total microparticles to differentiate Group 2 from Group 3 patients. Logistic regression using continuous variables yielded similar results (p = 0.05). This study demonstrates that plasma markers for DVT can be developed and achieve moderate sensitivity and specificity in diagnosing DVT. However for clinical applicability, the sensitivity/specificity will need to be improved. These studies also suggest the importance of soluble P-selectin in assessing DVT in humans.

PubMed Disclaimer

Publication types

Substances