Stress field forming of sector array transducers for vibro-acoustography
Abstract
This paper presents a study of the stress field forming of sector array transducers for vibro-acoustography applications. The system point-spread function (PSF) is given in terms of the dynamic radiation stress exerted on a point target by a dual ultrasound beam with slightly different frequencies. The radiation stress is calculated by assuming that the resulting ultrasound beam is a plane wave. The stress is proportional to the product of the velocity potential of each incident ultrasound beam. The beamforming and stress field forming of sector array transducers are analyzed through linear acoustics. An expression for the velocity potential produced by sector array transducers is derived. The vibro-acoustography PSF is evaluated numerically. A comparison between the PSF of a sector array and a confocal transducers is presented. The compared characteristics of the PSF are sidelobe levels, transverse, and in-depth spatial resolution. Indeed, one motivation to study sector transducers is the fact the depth-of-field of these transducers should be smaller than that of same size confocal transducers. An experimental setup was used to validate the theoretical PSF of sector array transducers. Results show that the measured PSF is in good agreement with the theoretical predications. Vibro-acoustography images of a breast-phantom by both transducers are presented and discussed.
Similar articles
-
Image formation in vibro-acoustography with depth-of-field effects.Comput Med Imaging Graph. 2006 Jul;30(5):321-7. doi: 10.1016/j.compmedimag.2006.08.001. Epub 2006 Sep 1. Comput Med Imaging Graph. 2006. PMID: 16949793
-
Multifrequency vibro-acoustography.IEEE Trans Med Imaging. 2006 Oct;25(10):1284-95. doi: 10.1109/tmi.2006.882142. IEEE Trans Med Imaging. 2006. PMID: 17024832
-
Comparison of stress field forming methods for vibro-acoustography.IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Mar;51(3):313-21. IEEE Trans Ultrason Ferroelectr Freq Control. 2004. PMID: 15128218
-
Critical issues in breast imaging by vibro-acoustography.Ultrasonics. 2006 Dec 22;44 Suppl 1:e217-20. doi: 10.1016/j.ultras.2006.06.021. Epub 2006 Jun 30. Ultrasonics. 2006. PMID: 16843513 Review.
-
Potential applications of vibro-acoustography in breast imaging.Technol Cancer Res Treat. 2005 Apr;4(2):151-8. doi: 10.1177/153303460500400204. Technol Cancer Res Treat. 2005. PMID: 15773784 Review.
Cited by
-
Implementation of vibro-acoustography on a clinical ultrasound system.IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Jun;58(6):1169-81. doi: 10.1109/TUFFC.2011.1927. IEEE Trans Ultrason Ferroelectr Freq Control. 2011. PMID: 21693399 Free PMC article.
-
Complex background suppression for vibro-acoustography images.Ultrasonics. 2015 Feb;56:456-72. doi: 10.1016/j.ultras.2014.09.014. Epub 2014 Sep 30. Ultrasonics. 2015. PMID: 25304993 Free PMC article.
-
Ultrasound Radiation Force for the Assessment of Bone Fracture Healing in Children: An In Vivo Pilot Study.Sensors (Basel). 2019 Feb 24;19(4):955. doi: 10.3390/s19040955. Sensors (Basel). 2019. PMID: 30813465 Free PMC article.
-
A Review of Vibro-acoustography and its Applications in Medicine.Curr Med Imaging Rev. 2011 Nov 1;7(4):350-359. doi: 10.2174/157340511798038648. Curr Med Imaging Rev. 2011. PMID: 22423235 Free PMC article.
-
Preliminary in vivo breast vibro-acoustography results with a quasi-2-d array transducer: a step forward.Ultrasound Med Biol. 2014 Dec;40(12):2819-29. doi: 10.1016/j.ultrasmedbio.2014.07.005. Ultrasound Med Biol. 2014. PMID: 25438862 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources