. 2006 Feb;81(2):481-8; discussion 489.
doi: 10.1016/j.athoracsur.2005.07.084.

Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival

Affiliations

Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival

Marc R Moon et al. Ann Thorac Surg. 2006 Feb.

Abstract

Background: The purpose of this study was to identify patient subgroups in which prosthesis-patient mismatch most influenced late survival.

Methods: Over a 12-year period, 1,400 consecutive patients underwent bioprosthetic (933 patients) or mechanical (467) aortic valve replacement. Prosthesis-patient mismatch was defined as prosthetic effective orifice area/body surface area less than 0.75 cm2/m2 and was present with 11% mechanical and 51% bioprosthetic valves.

Results: With bioprosthetic valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 68% +/- 7% mismatch versus 75% +/- 7% no mismatch, p < 0.02) but not older patients (p = 0.47). Similarly, with mechanical valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 62% +/- 11% versus 79% +/- 4%, p < 0.005) but not older patients (p = 0.26). For small patients (body surface area less than 1.7 m2), prosthesis-patient mismatch did not impact survival with bioprosthetic (p = 0.32) or mechanical (p = 0.71) valves. For average-size patients (body surface area 1.7 to 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with both bioprosthetic (p < 0.05) and mechanical (p < 0.005) valves. For large patients (body surface area greater than 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with mechanical (p < 0.04) but not bioprosthetic (p = 0.40) valves.

Conclusions: Prosthesis-patient mismatch had a negative impact on survival for young patients, but its impact on older patients was minimal. In addition, although prosthesis-patient mismatch was not important in small patients, prosthesis-patient mismatch negatively impacted survival for average-size patients and for large patients with mechanical valves.