Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Feb;46(2):236-43.
doi: 10.1111/j.1537-2995.2006.00716.x.

Washing platelets with new additive solutions: aspects on the in vitro quality after 48 hours of storage

Affiliations

Washing platelets with new additive solutions: aspects on the in vitro quality after 48 hours of storage

Jürgen Ringwald et al. Transfusion. 2006 Feb.

Abstract

Background: Rare clinical conditions cause the need for washed platelet (PLT) concentrates (PCs). Saline-washed PCs can only be stored shortly, however, owing to lack of substrates for PLT metabolism. New PLT additive solutions (PASs) contain such substrates and might be used alternatively. The in vitro quality of apheresis PCs washed with Composol-PS or modified PAS-III (PAS-IIIM) stored up to 48 hours after wash was compared.

Study design and methods: Twelve blood donors underwent two apheresis procedures (A and B) collecting 6.0 x 10(11) PLTs in 500 mL of plasma with a least 2 weeks in between. The PCs collected by Apheresis A were stored for 3 days and then split in two equal units before washing with Composol-PS or PAS-IIIM. The PCs collected by Apheresis B were split after collection. One unit was released for transfusion and 1 unit was stored unwashed up to Day 6 and used as reference unit. In vitro testing was performed before and after washing as well as 24 and 48 hours after wash.

Results: After 48 hours of postwash storage, the units washed with either PAS showed acceptable results for hypotonic shock response (HSR), P-selectin expression, and pH, whereas PLT aggregability was significantly impaired. Throughout the storage, unwashed units showed better in vitro quality. HSR and P-selectin expression were similar before and immediately after the washing procedure.

Conclusion: Based on these in vitro results, 48-hour postwash storage of washed PCs with the two PASs seems to be feasible. In vivo recovery studies, however, must confirm this finding in the future.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources