Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients
- PMID: 16443872
- DOI: 10.2337/diacare.29.02.06.dc05-1689
Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients
Abstract
Objective: To evaluate a fully automated algorithm for the establishment of tight glycemic control in critically ill patients and to compare the results with different routine glucose management protocols of three intensive care units (ICUs) across Europe (Graz, Prague, and London).
Research design and methods: Sixty patients undergoing cardiac surgery (age 67 +/- 9 years, BMI 27.7 +/- 4.9 kg/m2, 17 women) with postsurgery blood glucose levels >120 mg/dl (6.7 mmol/l) were investigated in three different ICUs (20 per center). Patients were randomized to either blood glucose management (target range 80-110 mg/dl [4.4-6.1 mmol/l]) by the fully automated model predictive control (MPC) algorithm (n = 30, 10 per center) or implemented routine glucose management protocols (n = 30, 10 per center). In all patients, arterial glucose was measured hourly to describe the glucose profile until the end of the ICU stay but for a maximum period of 48 h.
Results: Compared with routine protocols, MPC treatment resulted in a significantly higher percentage of time within the target glycemic range (% median [min-max]: 52 [17-92] vs. 19 [0-71]) over 0-24 h (P < 0.01). Improved glycemic control with MPC treatment was confirmed in patients remaining in the ICU for 48 h (0-24 h: 50 [17-71] vs. 21 [4-67], P < 0.05, and 24-48 h: 65 [38-96] vs. 25 [8-79], P < 0.05, for MPC [n = 16] vs. routine protocol [n = 13], respectively). Two hypoglycemic events (<54 mg/dl [3.0 mmol/l]) were observed with routine protocol treatment. No hypoglycemic event occurred with MPC.
Conclusions: The data suggest that the MPC algorithm is safe and effective in controlling glycemia in critically ill postsurgery patients.
Comment in
-
Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients: Response to Plank et al.Diabetes Care. 2006 Aug;29(8):1987. doi: 10.2337/dc06-0732. Diabetes Care. 2006. PMID: 16873825 No abstract available.
Similar articles
-
Blood glucose control by a model predictive control algorithm with variable sampling rate versus a routine glucose management protocol in cardiac surgery patients: a randomized controlled trial.J Clin Endocrinol Metab. 2007 Aug;92(8):2960-4. doi: 10.1210/jc.2007-0434. Epub 2007 Jun 5. J Clin Endocrinol Metab. 2007. PMID: 17550955 Clinical Trial.
-
Intensive insulin therapy: enhanced Model Predictive Control algorithm versus standard care.Intensive Care Med. 2009 Jan;35(1):123-8. doi: 10.1007/s00134-008-1236-z. Epub 2008 Jul 26. Intensive Care Med. 2009. PMID: 18661120 Clinical Trial.
-
Comparison of Space Glucose Control and Routine Glucose Management Protocol for Glycemic Control in Critically Ill Patients: A Prospective, Randomized Clinical Study.Chin Med J (Engl). 2017 Sep 5;130(17):2041-2049. doi: 10.4103/0366-6999.213422. Chin Med J (Engl). 2017. PMID: 28836546 Free PMC article. Clinical Trial.
-
Glucose control in the intensive care unit.Crit Care Med. 2009 May;37(5):1769-76. doi: 10.1097/CCM.0b013e3181a19ceb. Crit Care Med. 2009. PMID: 19325461 Review.
-
Towards closed-loop glycaemic control.Best Pract Res Clin Anaesthesiol. 2009 Mar;23(1):69-80. doi: 10.1016/j.bpa.2008.07.003. Best Pract Res Clin Anaesthesiol. 2009. PMID: 19449617 Review.
Cited by
-
Metrology in medicine: from measurements to decision, with specific reference to anesthesia and intensive care.Anesth Analg. 2015 Jan;120(1):66-75. doi: 10.1213/ANE.0000000000000477. Anesth Analg. 2015. PMID: 25625255 Free PMC article. Review.
-
The use of continuous glucose monitoring combined with computer-based eMPC algorithm for tight glucose control in cardiosurgical ICU.Biomed Res Int. 2013;2013:186439. doi: 10.1155/2013/186439. Epub 2013 Feb 20. Biomed Res Int. 2013. PMID: 23555075 Free PMC article.
-
Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time.Crit Care. 2009;13(5):R163. doi: 10.1186/cc8129. Epub 2009 Oct 12. Crit Care. 2009. PMID: 19822000 Free PMC article.
-
Tight glycaemic control: a prospective observational study of a computerised decision-supported intensive insulin therapy protocol.Crit Care. 2007;11(4):R75. doi: 10.1186/cc5964. Crit Care. 2007. PMID: 17623086 Free PMC article.
-
In silico testing--impact on the progress of the closed loop insulin infusion for critically ill patients project.J Diabetes Sci Technol. 2008 May;2(3):417-23. doi: 10.1177/193229680800200311. J Diabetes Sci Technol. 2008. PMID: 19885206 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical