Objective: To compare transcervical Foley bulb with and without extra-amniotic saline infusion for induction of labor in patients with an unfavorable cervix.
Methods: Women who presented for induction of labor with Bishop score less than 5 were randomly assigned to receive Foley alone or Foley with extra-amniotic saline infusion for induction of labor. Primary outcome was time from start of induction to vaginal delivery. Secondary outcomes were cesarean delivery rates, incidence of chorioamnionitis, Apgar scores at 1 and 5 minutes, and adverse events.
Results: One hundred forty women completed the study. Time from induction to vaginal delivery was 16.58 (+/- 7.55) hours in the extra-amniotic saline infusion group compared with 21.47 (+/- 9.95) hours in the Foley group (P < .01). Chorioamnionitis occurred in 4 of 66 (6.1%) women in the extra-amniotic saline infusion group compared with 12 of 74 (16.2%) women in the Foley group (P = .067). Cesarean delivery rate was 21.2% versus 20.1% in the extra-amniotic saline infusion and Foley groups, respectively (P = 1.0). Median 1-minute and 5-minute Apgar scores were 9 in both groups. Adverse events were rare and unrelated to method of induction.
Conclusion: Induction of labor by using Foley with extra-amniotic saline infusion results in shorter induction-to-vaginal-delivery time than Foley alone, without affecting cesarean delivery rates.
Level of evidence: II-I
Similar articles
-
Transcervical Foley catheter with and without extraamniotic saline infusion for labor induction: a randomized controlled trial.Obstet Gynecol. 2007 Sep;110(3):558-65. doi: 10.1097/01.AOG.0000278077.30890.87. Obstet Gynecol. 2007. PMID: 17766600 Clinical Trial.
-
Labor induction in women with an unfavorable Bishop score: randomized controlled trial of intrauterine Foley catheter with concurrent oxytocin infusion versus Foley catheter with extra-amniotic saline infusion with concurrent oxytocin infusion.Am J Obstet Gynecol. 2004 Jul;191(1):225-9. doi: 10.1016/j.ajog.2003.12.039. Am J Obstet Gynecol. 2004. PMID: 15295370 Clinical Trial.
-
Increased rates of chorioamnionitis with extra-amniotic saline infusion method of labor induction.Obstet Gynecol. 2004 Apr;103(4):724-8. doi: 10.1097/01.AOG.0000118308.65550.f6. Obstet Gynecol. 2004. PMID: 15051565
-
Other mechanical methods for pre-induction cervical ripening.Semin Perinatol. 2015 Oct;39(6):444-9. doi: 10.1053/j.semperi.2015.07.006. Epub 2015 Sep 2. Semin Perinatol. 2015. PMID: 26341067 Review.
-
Amniotic membrane sweeping.Semin Perinatol. 2015 Oct;39(6):466-70. doi: 10.1053/j.semperi.2015.07.010. Epub 2015 Sep 11. Semin Perinatol. 2015. PMID: 26365011 Review.
Cited by
-
Labor induction utilizing the Foley balloon: a randomized trial comparing standard placement versus immediate removal.J Perinatol. 2015 Jun;35(6):390-5. doi: 10.1038/jp.2014.229. Epub 2015 Jan 8. J Perinatol. 2015. PMID: 25569680 Clinical Trial.
-
Comparing membrane sweep and cervical massage in preventing the need for formal labour induction in uncomplicated pregnancy at term: Secondary analysis of a randomized controlled trial.PLoS One. 2025 May 20;20(5):e0324172. doi: 10.1371/journal.pone.0324172. eCollection 2025. PLoS One. 2025. PMID: 40392830 Free PMC article. Clinical Trial.
-
Mechanical methods for induction of labour.Cochrane Database Syst Rev. 2019 Oct 18;10(10):CD001233. doi: 10.1002/14651858.CD001233.pub3. Cochrane Database Syst Rev. 2019. Update in: Cochrane Database Syst Rev. 2023 Mar 30;3:CD001233. doi: 10.1002/14651858.CD001233.pub4. PMID: 31623014 Free PMC article. Updated. Review.
-
A randomized controlled trial of foley catheter, extra-amniotic saline infusion and prostaglandin e2 suppository for labor induction.J Family Reprod Health. 2013 Jun;7(2):49-55. J Family Reprod Health. 2013. PMID: 24971103 Free PMC article.
-
A lariat-based dilatation device for hysteroscopy: an in vitro study.Ann Transl Med. 2019 Sep;7(18):462. doi: 10.21037/atm.2019.08.30. Ann Transl Med. 2019. PMID: 31700898 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials