High-throughput multi-antigen microfluidic fluorescence immunoassays
- PMID: 16454045
- DOI: 10.2144/000112071
High-throughput multi-antigen microfluidic fluorescence immunoassays
Abstract
Here we describe the development of a high-throughput multi-antigen microfluidic fluorescence immunoassay system. A 100-chamber polydimethylsiloxane (PDMS) chip performs up to 5 tests for each of 10 samples. In this particular study system, the specificity of detection was demonstrated, and calibration curves were produced for C-reactive protein (CRP), prostate-specific antigen (PSA), ferritin, and vascular endothelial growth factor (VEGF). The measurements show sensitivity at and below clinically normal levels (with a signal-to-noise ratio >8 at as low as 10 pM antigen concentration). The chip uses 100 nL per sample for all tests. The developed system is an important step toward derivative immunoassay applications in scientific research and "point-of-care" testing in medicine.
Similar articles
-
Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates.Lab Chip. 2009 Dec 7;9(23):3330-7. doi: 10.1039/b906523g. Epub 2009 Aug 21. Lab Chip. 2009. PMID: 19904397
-
Disposable polydimethylsiloxane/silicon hybrid chips for protein detection.Biosens Bioelectron. 2005 Oct 15;21(4):574-80. doi: 10.1016/j.bios.2004.12.010. Epub 2005 Jan 22. Biosens Bioelectron. 2005. PMID: 16202870
-
Internally calibrated quantification of VEGF in human plasma by fluorescence immunoassays in disposable elastomeric microfluidic devices.J Chromatogr B Analyt Technol Biomed Life Sci. 2010 Jan 15;878(2):258-63. doi: 10.1016/j.jchromb.2009.08.038. Epub 2009 Aug 29. J Chromatogr B Analyt Technol Biomed Life Sci. 2010. PMID: 19748324 Free PMC article.
-
Immunoassays in microfluidic systems.Anal Bioanal Chem. 2010 Jun;397(3):991-1007. doi: 10.1007/s00216-010-3678-8. Epub 2010 Apr 27. Anal Bioanal Chem. 2010. PMID: 20422163 Review.
-
Miniaturized immunoassays: moving beyond the microplate.Bioanalysis. 2012 Jan;4(2):177-88. doi: 10.4155/bio.11.301. Bioanalysis. 2012. PMID: 22250800 Review.
Cited by
-
Electrical microfluidic pressure gauge for elastomer microelectromechanical systems.J Appl Phys. 2007;102(8):84909-849094. doi: 10.1063/1.2801008. J Appl Phys. 2007. PMID: 19587835 Free PMC article.
-
Antinuclear antibodies and their detection methods in diagnosis of connective tissue diseases: a journey revisited.Diagn Pathol. 2009 Jan 2;4:1. doi: 10.1186/1746-1596-4-1. Diagn Pathol. 2009. PMID: 19121207 Free PMC article.
-
Rapid detection of influenza A virus infection utilizing an immunomagnetic bead-based microfluidic system.Biosens Bioelectron. 2011 May 15;26(9):3900-7. doi: 10.1016/j.bios.2011.03.006. Epub 2011 Mar 16. Biosens Bioelectron. 2011. PMID: 21466957 Free PMC article.
-
Ultrasensitive melanoma biomarker detection using a microchip SERS immunoassay with anisotropic Au-Ag alloy nanoboxes.RSC Adv. 2020 Aug 4;10(48):28778-28785. doi: 10.1039/d0ra05032f. eCollection 2020 Aug 3. RSC Adv. 2020. PMID: 35520058 Free PMC article.
-
Antibodies, repertoires and microdevices in antibody discovery and characterization.Lab Chip. 2024 Feb 27;24(5):1207-1225. doi: 10.1039/d3lc00887h. Lab Chip. 2024. PMID: 38165819 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous