The case for venous rather than arterial blood gases in diabetic ketoacidosis
- PMID: 16454777
- DOI: 10.1111/j.1742-6723.2006.00803.x
The case for venous rather than arterial blood gases in diabetic ketoacidosis
Abstract
Objectives: For patients with diabetic ketoacidosis (DKA), arterial blood gas (BG) sampling for measurement of pH and bicarbonate has been considered an essential part of initial evaluation and monitoring of progress. There is growing evidence that venous values can be clinically acceptable alternatives to arterial measurements. This article summarizes the recent evidence regarding the validity of venous BG sampling in DKA.
Methods: Medline search for the years 1995 to present, hand search of reference lists, search of on-line evidence-based medicine sites.
Results: In patients with DKA the weighted average difference between arterial and venous pH was 0.02 pH units (95% limits of agreement -0.009 to +0.021 pH units) and between arterial and venous bicarbonate was -1.88 mEq/L.
Conclusions: There is reasonable evidence that venous and arterial pH have sufficient agreement as to be clinically interchangeable in patients with DKA who are haemodynamically stable and without respiratory failure. There is some evidence that venous and arterial bicarbonate also agree closely in DKA but this requires confirmation.
Similar articles
-
Are arterial and venous samples clinically equivalent for the estimation of pH, serum bicarbonate and potassium concentration in critically ill patients?Diabet Med. 2012 Jan;29(1):32-5. doi: 10.1111/j.1464-5491.2011.03390.x. Diabet Med. 2012. PMID: 21781155
-
Agreement between bicarbonate measured on arterial and venous blood gases.Emerg Med Australas. 2004 Oct-Dec;16(5-6):407-9. doi: 10.1111/j.1742-6723.2004.00642.x. Emerg Med Australas. 2004. PMID: 15537402 Clinical Trial.
-
Diagnostic accuracy of venous blood gas electrolytes for identifying diabetic ketoacidosis in the emergency department.Acad Emerg Med. 2011 Oct;18(10):1105-8. doi: 10.1111/j.1553-2712.2011.01158.x. Epub 2011 Sep 26. Acad Emerg Med. 2011. PMID: 21951652
-
Review article: Can venous blood gas analysis replace arterial in emergency medical care.Emerg Med Australas. 2010 Dec;22(6):493-8. doi: 10.1111/j.1742-6723.2010.01344.x. Emerg Med Australas. 2010. PMID: 21143397 Review.
-
Arterial blood gas analysis: are its values needed for the management of diabetic ketoacidosis?Ann Emerg Med. 2005 May;45(5):550-1. doi: 10.1016/j.annemergmed.2004.11.005. Ann Emerg Med. 2005. PMID: 15855956 Review. No abstract available.
Cited by
-
Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.J Feline Med Surg. 2017 Aug;19(8):831-840. doi: 10.1177/1098612X16663269. Epub 2016 Aug 1. J Feline Med Surg. 2017. PMID: 27542821 Free PMC article.
-
Clinical applications of blood gas analysis: a comparative review of arterial and venous blood gas monitoring in critical care.Acute Crit Care. 2025 May;40(2):153-159. doi: 10.4266/acc.000900. Epub 2025 May 30. Acute Crit Care. 2025. PMID: 40494592 Free PMC article.
-
Respiratory failure in diabetic ketoacidosis.World J Diabetes. 2015 Jul 25;6(8):1009-23. doi: 10.4239/wjd.v6.i8.1009. World J Diabetes. 2015. PMID: 26240698 Free PMC article. Review.
-
Validity of venous blood gas analysis for diagnosis of acid-base imbalance in children admitted to pediatric intensive care unit.World J Pediatr. 2008 May;4(2):114-7. doi: 10.1007/s12519-008-0022-x. World J Pediatr. 2008. PMID: 18661766
-
Management of Diabetic Ketoacidosis in Adults: A Narrative Review.Saudi J Med Med Sci. 2020 Sep-Dec;8(3):165-173. doi: 10.4103/sjmms.sjmms_478_19. Epub 2020 Aug 20. Saudi J Med Med Sci. 2020. PMID: 32952507 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources