What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging
- PMID: 16455424
- DOI: 10.1016/j.echo.2005.08.020
What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging
Abstract
Background: Left ventricular (LV) volumes have important prognostic implications, but are commonly underestimated. We sought accuracy and reproducibility of LV volume measurement by live 3-dimensional (3D) echocardiography (3DE) and TI-201 single photon emission computed tomography (SPECT), compared with cardiac magnetic resonance imaging (MRI).
Methods: In all, 30 patients (age 62 +/- 9 years, 23 men) underwent LV volume assessment with 3DE, SPECT, and cardiac MRI after myocardial infarction. LV volumes were measured using a semiautomated border detection algorithm for 3DE, gated SPECT software for SPECT, and a 3D display for MRI. Results of 3DE and SPECT volumes were compared with MRI as the standard of reference.
Results: The 3DE volumes showed excellent correlation with cardiac MRI (end-diastolic volume [EDV], r = 0.90, P = .001; end-systolic volume [ESV], r = 0.94, P = .001), as did SPECT (EDV, r = 0.89, P = .001; ESV, r = 0.95, P = .001). However, both 3DE and SPECT underestimated LV volumes. The mean MRI EDV was 179 +/- 56 mL compared with 3DE (mean difference, -10 +/- 26 mL, P = .04) and SPECT (mean difference, -58 +/- 28 mL, P < .001). There was a significant difference between SPECT EDV and 3DE (mean difference, -48 +/- 31 mL, P < .001). The mean MRI ESV was 96 +/- 54 mL and this was underestimated by SPECT (mean difference, -22 +/- 19 mL, P < .001), but not by 3DE (mean difference, -0.9 +/- 19 mL, P = not significant). ESV was also underestimated when SPECT was compared with 3DE (mean difference, -22 +/- 27 mL, P < .001). The results of 3DE were reproducible with excellent intraobserver (ESV, r = 0.98, -2 +/- 6 mL; EDV, r = 0.98, -1 +/- 6 mL, P = .001) and interobserver (ESV, r = 0.97, -2 +/- 6 mL; EDV, r = 0.95, -3 +/- 10 mL, P = .001) correlation.
Conclusion: We have shown that 3DE is accurate and reproducible for the measurement of LV volumes for risk assessment in chronic ischemic heart disease and dilated cardiomyopathy. Furthermore, 3DE is more accurate than TI-201 SPECT with less underestimation of LV volumes.
Similar articles
-
Left ventricular functional analysis with 16- and 64-row multidetector computed tomography: comparison with gated single-photon emission computed tomography.J Comput Assist Tomogr. 2009 Jan-Feb;33(1):8-14. doi: 10.1097/RCT.0b013e3181624ad0. J Comput Assist Tomogr. 2009. PMID: 19188778
-
Reconstructed versus real-time 3-dimensional echocardiography: comparison with magnetic resonance imaging.J Am Soc Echocardiogr. 2007 Jul;20(7):862-8. doi: 10.1016/j.echo.2006.12.010. J Am Soc Echocardiogr. 2007. PMID: 17617313
-
Quantification of left ventricular volumes and ejection fraction using freehand transthoracic three-dimensional echocardiography: comparison with magnetic resonance imaging.J Am Soc Echocardiogr. 2003 Feb;16(2):101-9. doi: 10.1067/mje.2003.7. J Am Soc Echocardiogr. 2003. PMID: 12574735
-
Comparison of global and regional left ventricular function assessed by gated-SPECT and 2-D echocardiography.Rev Port Cardiol. 2000 Feb;19 Suppl 1:I39-46. Rev Port Cardiol. 2000. PMID: 10750438 Review.
-
Detection of cardiovascular disease in elite athletes using cardiac magnetic resonance imaging.Rofo. 2013 Dec;185(12):1167-74. doi: 10.1055/s-0033-1350130. Epub 2013 Jul 29. Rofo. 2013. PMID: 23897528 Review.
Cited by
-
Single photon emission computed tomography: an alternative imaging modality in left ventricular evaluation.Vasc Health Risk Manag. 2008;4(5):1069-72. doi: 10.2147/vhrm.s3152. Vasc Health Risk Manag. 2008. PMID: 19183754 Free PMC article. Review.
-
Flow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics.Cardiovasc Ultrasound. 2008 Apr 4;6:13. doi: 10.1186/1476-7120-6-13. Cardiovasc Ultrasound. 2008. PMID: 18394157 Free PMC article. Clinical Trial.
-
Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy.Eur J Nucl Med Mol Imaging. 2009 Oct;36(10):1611-21. doi: 10.1007/s00259-009-1136-7. Epub 2009 Apr 18. Eur J Nucl Med Mol Imaging. 2009. PMID: 19377903
-
Real time 3D echocardiography (RT3D) for assessment of ventricular and vascular function in hypertensive and heart failure patients.Cardiovasc Ultrasound. 2012 Jun 28;10:27. doi: 10.1186/1476-7120-10-27. Cardiovasc Ultrasound. 2012. PMID: 22742054 Free PMC article.
-
Assessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography - a phantom and clinical study.Cardiovasc Ultrasound. 2008 Jun 4;6:26. doi: 10.1186/1476-7120-6-26. Cardiovasc Ultrasound. 2008. PMID: 18533014 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical