Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Jun;27(6):1244-50.
doi: 10.1183/09031936.06.00136905. Epub 2006 Feb 2.

Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction?

Affiliations
Free article

Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction?

J E Hansen et al. Eur Respir J. 2006 Jun.
Free article

Abstract

It has been suggested that forced expiratory volume in six seconds (FEV(6)) should be substituted for forced vital capacity (FVC) to measure fractions of timed expired volume for airflow obstruction detection. The present authors hypothesised that this recommendation might be questionable because flow after 6 s of forced expiration from more diseased lung units with the longest time constants was most meaningful and should not be ignored. Furthermore, previous studies comparing FEV(6) and FVC included few subjects with mild or no disease. The present study used spirometric data from the USA Third National Health and Nutrition Evaluation Survey with prior published ethnicity- and sex-specific equations for FEV(1)/FEV(6), FEV(1)/FVC and FEV(3)/FVC, and new equations for FEV(3)/FEV(6), all derived from approximately 4,000 adult never-smokers aged 20-80 yrs. At 95% confidence intervals, 21.3% of 3,515 smokers and 41.3% of smokers aged >51 yrs had airway obstruction; when comparing FEV(1)/FEV(6) with FEV(1)/FVC, 13.5% were concurrently abnormal, 1.5% were false positives and 4.1% were false negatives; and when comparing FEV(3)/FEV(6) with FEV(3)/FVC, 11.6% were concurrently abnormal, 3.3% were false positives and 5.7% were false negatives. Substituting forced expiratory volume in six seconds for forced vital capacity to determine the fractional rates of exhaled volumes reduces the sensitivity of spirometry to detect airflow obstruction, especially in older individuals and those with lesser obstruction.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

LinkOut - more resources