Physiological effects of vibration in subjects with cystic fibrosis
- PMID: 16455834
- DOI: 10.1183/09031936.06.00083605
Physiological effects of vibration in subjects with cystic fibrosis
Abstract
The physiological mechanisms by which vibration and other physiotherapy interventions may clear secretions in subjects with cystic fibrosis are unknown. The main aim of this study was to compare the expiratory flow rates and frequencies of airflow oscillation of vibration to those of Acapella(R), Flutter(R), positive expiratory pressure and percussion. Respiratory flow rates were measured during interventions, the order of which was randomised. The oscillation of the airflow of the interventions was determined by frequency spectral analysis. In 18 young adult subjects with cystic fibrosis, the mean peak expiratory flow rate of vibration was greater than Flutter(R), percussion, Acapella(R) and positive expiratory pressure. The mean+/-sd of the oscillation of the airflow of vibration (8.4+/-0.4 Hz) was lower than Acapella(R) (13.5+/-1.7 Hz) and Flutter(R) (11.3+/-1.5 Hz) but similar to percussion (7.3+/-0.3 Hz). Theoretically, the higher peak expiratory flow rate of vibration compared to the other physiotherapy interventions may promote secretion clearance. In addition, the frequency of oscillation of vibration was within the range demonstrated to increase mucus transport. This study has provided some evidence for the physiological rationale for the use of vibration to aid secretion clearance.
Comment in
-
Airway clearance techniques in cystic fibrosis.Eur Respir J. 2006 Jun;27(6):1082-3. doi: 10.1183/09031936.06.00046706. Eur Respir J. 2006. PMID: 16772386 No abstract available.
Similar articles
-
The influence of Flutter®VRP1 components on mucus transport of patients with bronchiectasis.Respir Med. 2011 Sep;105(9):1316-21. doi: 10.1016/j.rmed.2011.04.017. Respir Med. 2011. PMID: 21641196 Clinical Trial.
-
Performance analysis of the Flutter VRP1 under different flows and angles.Respir Care. 2008 Mar;53(3):316-23. Respir Care. 2008. PMID: 18291047
-
Performance comparison of two oscillating positive expiratory pressure devices: Acapella versus Flutter.Respir Care. 2003 Feb;48(2):124-30. Respir Care. 2003. PMID: 12556253
-
Airway clearance devices in cystic fibrosis.Paediatr Respir Rev. 2007 Mar;8(1):17-23. doi: 10.1016/j.prrv.2007.02.003. Epub 2007 Mar 21. Paediatr Respir Rev. 2007. PMID: 17419974 Review.
-
Airway clearance therapy in cystic fibrosis patients.Acta Biomed. 2009 Aug;80(2):102-6. Acta Biomed. 2009. PMID: 19848046 Review.
Cited by
-
Effect of manual chest wall compression in participants with chronic obstructive pulmonary disease.J Phys Ther Sci. 2018 Nov;30(11):1349-1354. doi: 10.1589/jpts.30.1349. Epub 2018 Nov 6. J Phys Ther Sci. 2018. PMID: 30464362 Free PMC article.
-
Positive expiratory pressure therapy versus other airway clearance techniques for bronchiectasis.Cochrane Database Syst Rev. 2017 Sep 27;9(9):CD011699. doi: 10.1002/14651858.CD011699.pub2. Cochrane Database Syst Rev. 2017. PMID: 28952156 Free PMC article.
-
Use of an oscillatory PEP device to enhance bronchial hygiene in a patient of post-H1NI pneumonia and acute respiratory distress syndrome with pneumothorax.BMJ Case Rep. 2014 Mar 7;2014:bcr2013202598. doi: 10.1136/bcr-2013-202598. BMJ Case Rep. 2014. PMID: 24717858 Free PMC article.
-
Respiratory physiotherapy with Vibration belts in the critical patient Covid-19 in the prone position.Rev Esp Anestesiol Reanim (Engl Ed). 2020 Oct;67(8):481-482. doi: 10.1016/j.redar.2020.06.014. Epub 2020 Jul 9. Rev Esp Anestesiol Reanim (Engl Ed). 2020. PMID: 32798073 Free PMC article. No abstract available.
-
Oscillating devices for airway clearance in people with cystic fibrosis.Cochrane Database Syst Rev. 2017 May 4;5(5):CD006842. doi: 10.1002/14651858.CD006842.pub4. Cochrane Database Syst Rev. 2017. Update in: Cochrane Database Syst Rev. 2020 Apr 30;4:CD006842. doi: 10.1002/14651858.CD006842.pub5. PMID: 28471492 Free PMC article. Updated.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical