High analytical sensitivity and low rates of inhibition may contribute to detection of Chlamydia trachomatis in significantly more women by the APTIMA Combo 2 assay
- PMID: 16455891
- PMCID: PMC1392683
- DOI: 10.1128/JCM.44.2.400-405.2006
High analytical sensitivity and low rates of inhibition may contribute to detection of Chlamydia trachomatis in significantly more women by the APTIMA Combo 2 assay
Abstract
The clinical sensitivity of nucleic acid amplification tests may be determined by analytical sensitivity and inhibitors in patient samples. We established endpoints for detection of propagated Chlamydia trachomatis L2 434, diluted according to swab and urine protocols for APTIMA Combo 2 (AC2), ProbeTec ET (PT), and Amplicor (AMP) assays. AC2 was 1,000-fold more sensitive than PT and 10-fold more sensitive than AMP on mock swab specimens. For urine, AC2 analytical sensitivity was 100-fold greater than those of the other assays. Spiking an aliquot of each clinical-trial sample from 298 women demonstrated inhibition rates in first-void urine (FVU), cervical swabs (CS), and vaginal swabs (VS) of 12.1%, 12.8%, and 10.4% for AMP; 27.2%, 2%, and 2%, for PT; and 0.3%, 1.7%, and 1.3% for AC2. Inhibition of our C. trachomatis spike and the PT or AMP amplification controls from the manufacturers showed less than 50% correlation. Using an infected-patient reference standard (a specimen positive in at least two tests or a single test positive in two of three samples) in AC2, the VS identified 68/69 (98.6%) infected women compared to CS (89.9%) or FVU (81.2%). Significantly fewer women were identified by PT (65.2%, 63.8%, and 66.7%) or AMP (65.2%, 59.4%, and 56.5%) with the three specimens. By individual specimen type, AC2 confirmed virtually all PT- and AMP-positive specimens, but rates of AC2 confirmation by AMP or PT ranged from 62.9 to 80.3%. The AC2 test identified significantly more women infected with C. trachomatis (P = 0.001). Vaginal swabs appear to be the specimen of choice for screening.
Figures
Similar articles
-
Abilities of APTIMA, AMPLICOR, and ProbeTec assays to detect Chlamydia trachomatis and Neisseria gonorrhoeae in PreservCyt ThinPrep Liquid-based Pap samples.J Clin Microbiol. 2007 Aug;45(8):2355-8. doi: 10.1128/JCM.00405-07. Epub 2007 May 30. J Clin Microbiol. 2007. PMID: 17537943 Free PMC article.
-
Validation of the APTIMA Combo 2 assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in SurePath liquid-based pap test samples taken with different collection devices.Sex Transm Dis. 2009 Sep;36(9):581-3. doi: 10.1097/OLQ.0b013e3181a4c3fc. Sex Transm Dis. 2009. PMID: 19661842
-
Urinary inhibitors of polymerase chain reaction and ligase chain reaction and testing of multiple specimens may contribute to lower assay sensitivities for diagnosing Chlamydia trachomatis infected women.Mol Cell Probes. 1997 Aug;11(4):243-9. doi: 10.1006/mcpr.1997.0109. Mol Cell Probes. 1997. PMID: 9281409 Clinical Trial.
-
[DNA amplification in the diagnosis of urogenital Chlamydia trachomatis infection].Tidsskr Nor Laegeforen. 1999 Jun 20;119(16):2350-6. Tidsskr Nor Laegeforen. 1999. PMID: 10414201 Review. Norwegian.
-
APTIMA transcription-mediated amplification assays for Chlamydia trachomatis and Neisseria gonorrhoeae.Expert Rev Mol Diagn. 2006 Jul;6(4):519-25. doi: 10.1586/14737159.6.4.519. Expert Rev Mol Diagn. 2006. PMID: 16824026 Review.
Cited by
-
Comparison of three assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in SurePath Pap samples and the role of pre- and postcytology testing.J Clin Microbiol. 2012 Apr;50(4):1281-4. doi: 10.1128/JCM.06595-11. Epub 2012 Jan 18. J Clin Microbiol. 2012. PMID: 22259215 Free PMC article.
-
Characteristics of the m2000 automated sample preparation and multiplex real-time PCR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.J Clin Microbiol. 2007 Mar;45(3):747-51. doi: 10.1128/JCM.01956-06. Epub 2007 Jan 3. J Clin Microbiol. 2007. PMID: 17202273 Free PMC article.
-
Retrospective assessment of transcription-mediated amplification-based screening for Trichomonas vaginalis in male sexually transmitted infection clinic patients.J Clin Microbiol. 2013 Jun;51(6):1855-60. doi: 10.1128/JCM.00455-13. Epub 2013 Apr 3. J Clin Microbiol. 2013. PMID: 23554208 Free PMC article.
-
Female epidemiology of transcription-mediated amplification-based Trichomonas vaginalis detection in a metropolitan setting with a high prevalence of sexually transmitted infection.J Clin Microbiol. 2012 Dec;50(12):3927-31. doi: 10.1128/JCM.02078-12. Epub 2012 Sep 26. J Clin Microbiol. 2012. PMID: 23015673 Free PMC article.
-
Chlamydia trachomatis variant not detected by plasmid based nucleic acid amplification tests: molecular characterisation and failure of single dose azithromycin.Sex Transm Infect. 2007 Jul;83(4):339-43. doi: 10.1136/sti.2007.026435. Epub 2007 Jun 13. Sex Transm Infect. 2007. PMID: 17567684 Free PMC article.
References
-
- Boyadzhyan, B., T. Yashina, J. H. Yatabe, M. Patnaik, and C. S. Hill. 2004. Comparison of the APTIMA CT and GC assays with the APTIMA combo 2 assay, the Abbott LCx assay, and direct fluorescent-antibody and culture assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae. J. Clin. Microbiol. 42:3089-3093. - PMC - PubMed
-
- Carder, C., A. J. Robinson, C. Broughton, J. M. Stephenson, and G. L. Ridgway. 1999. Evaluation of self-taken samples for the presence of genital Chlamydia trachomatis infection in women using the ligase chain reaction assay. Int. J. STD AIDS 10:776-779. - PubMed
-
- Chan, E. L., K. Brandt, K. Olienus, N. Antonishyn, and G. B. Horsman. 2000. Performance characteristics of the Becton Dickinson ProbeTec System for direct detection of Chlamydia trachomatis and Neisseria gonorrhoeae in male and female urine specimens in comparison with the Roche Cobas System. Arch. Pathol. Lab. Med. 124:1649-1652. - PubMed
-
- Chong, S., D. Jang, X. Song, J. Mahony, A. Petrich, P. Barriga, and M. Chernesky. 2003. Specimen processing and concentration of Chlamydia trachomatis added can influence false-negative rates in the LCx assay but not in the APTIMA Combo 2 assay when testing for inhibitors. J. Clin. Microbiol. 41:778-782. - PMC - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical