Clinical Trial
. 1991;18(3):178-83.
doi: 10.1007/BF02262728.

Assessment of ventricular function with first-pass radionuclide angiography using technetium 99m hexakis-2-methoxyisobutylisonitrile: a European multicentre study

Affiliations
Clinical Trial

Assessment of ventricular function with first-pass radionuclide angiography using technetium 99m hexakis-2-methoxyisobutylisonitrile: a European multicentre study

G Bisi et al. Eur J Nucl Med. 1991.

Abstract

In the context of a multicentre study on the use of technetium 99m hexakis-2-methoxyisobutylisonitrile (99mTc-Sestamibi), we evaluated the accuracy of the ventricular function assessed at rest by means of first-pass radionuclide angiocardiography acquired during the injection of the tracer for myocardial perfusion scintigraphy. The results were compared with first-pass studies performed using reference tracers sodium pertechnetate Tc 99m or technetium 99m diethylene triamine penta-acetic acid or with gated radionuclide angiocardiography. A total of 66 patients of the 105 enrolled in the study could be evaluated. The comparison of the first-pass studies was possible in 33 subjects with regard to the left ventricular ejection fraction, yielding r = 0.909 (P less than 10(-6)), and in 22 cases with regard to the right ventricular ejection fraction, yielding r = 0.712 (P less than 0.001). The comparison between the first-pass study using 99mTc-Sestamibi and the equilibrium gated radionuclide angiocardiography was possible for the left ventricular ejection fraction in 26 cases, with r = 0.937 (P less than 10(-6)), and for the right ventricular ejection fraction in 15 subjects, with r = 0.783 (P less than 0.001). In conclusion, the assessment of ventricular function performed by acquiring a first-pass radionuclide angiocardiograph during the injection of 99mTc-Sestamibi for perfusion myocardial scintigraphy can be considered reliable and accurate, when compared with the usually employed techniques. This result confirms the feasibility of a combined evaluation of perfusion and function at rest and during stress testing, which represents one of the most interesting advantages offered by the use of 99mTc-Sestamibi.

PubMed Disclaimer

Similar articles

Cited by

References