. 2006 Mar;4(3):671-7.
doi: 10.1111/j.1538-7836.2006.01794.x.

Isolation and enumeration of circulating endothelial cells by immunomagnetic isolation: proposal of a definition and a consensus protocol

Affiliations
Free article
Comparative Study

Isolation and enumeration of circulating endothelial cells by immunomagnetic isolation: proposal of a definition and a consensus protocol

A Woywodt et al. J Thromb Haemost. 2006 Mar.
Free article

Abstract

Background: Circulating endothelial cells (CECs) have been identified as markers of vascular damage in a variety of disorders, such as myocardial infarction, vasculitis, and transplantation. CD146-driven immunomagnetic isolation has gained widespread use, but the technique is hampered by the lack of a definition of CECs and the absence of a consensus for their enumeration.

Aim: To evaluate several variables influencing immunomagnetic isolation of CECs, formulate a definition for CECs and propose a consensus protocol for their enumeration.

Methods: We devised a protocol based on CD146-driven immunomagnetic isolation and a subsequent confirmatory step with Ulex-Europaeus-Lectin-1 staining. In a multi-center effort, we evaluated the preanalytical and analytical phases of this protocol. We evaluated the effects of storage, anticoagulation and density centrifugation, and compiled previous experience with this technique.

Results: Our protocol permitted unequivocal identification of CECs with acceptable reproducibility. There was an effect of storage time in that median cell numbers declined to only 87.5% of their baseline values during 24 h of storage at 4 degrees C. Recovery was lower with citrate than with ethylene-diamine tetra-acetic acid after 4 h of storage; density centrifugation was also associated with lower recovery. We provide a comprehensive list of technical recommendations and potential pitfalls. Finally, based on our experience with this protocol and a recent consensus workshop, we formulated a working definition for CECs.

Conclusion: Our work represents an important step toward consensus regarding the CECs. Our recommendations represent the experience of three major centers and should now be scrutinized by others in the field.