Image quality measurements and metrics in full field digital mammography: an overview
- PMID: 16461531
- DOI: 10.1093/rpd/nci711
Image quality measurements and metrics in full field digital mammography: an overview
Abstract
This paper gives an overview of test procedures developed to assess the performance of full field digital mammography systems. We make a distinction between tests of the individual components of the imaging chain and global system tests. Most tests are not yet fully standardised. Where possible, we illustrate the test methodologies on a selenium flat-panel system.
Similar articles
-
A comparison between objective and subjective image quality measurements for a full field digital mammography system.Phys Med Biol. 2006 May 21;51(10):2441-63. doi: 10.1088/0031-9155/51/10/006. Epub 2006 Apr 26. Phys Med Biol. 2006. PMID: 16675862
-
Automated analysis of phantom images for the evaluation of long-term reproducibility in digital mammography.Phys Med Biol. 2007 Mar 7;52(5):1387-407. doi: 10.1088/0031-9155/52/5/012. Epub 2007 Feb 8. Phys Med Biol. 2007. PMID: 17301461
-
Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.Radiat Prot Dosimetry. 2005;114(1-3):383-8. doi: 10.1093/rpd/nch555. Radiat Prot Dosimetry. 2005. PMID: 15933142
-
Digital mammography.Radiol Clin North Am. 2004 Sep;42(5):871-84, vi. doi: 10.1016/j.rcl.2004.06.004. Radiol Clin North Am. 2004. PMID: 15337422 Review.
-
Artifacts in digital mammography.JBR-BTR. 2008 Nov-Dec;91(6):262-3. JBR-BTR. 2008. PMID: 19203002 Review.
Cited by
-
Figure of image quality and information capacity in digital mammography.Biomed Res Int. 2014;2014:634856. doi: 10.1155/2014/634856. Epub 2014 May 8. Biomed Res Int. 2014. PMID: 24895593 Free PMC article.
-
Digital mammography: what do we and what don't we know?Eur Radiol. 2007 Aug;17(8):1931-42. doi: 10.1007/s00330-007-0586-1. Epub 2007 Feb 14. Eur Radiol. 2007. PMID: 17429645 Review.
-
Initial quality performance results using a phantom to simulate chest computed radiography.J Med Phys. 2011 Jan;36(1):22-8. doi: 10.4103/0971-6203.75468. J Med Phys. 2011. PMID: 21430855 Free PMC article.
-
Does digital mammography in a decentralized breast cancer screening program lead to screening performance parameters comparable with film-screen mammography?Eur Radiol. 2010 Oct;20(10):2307-14. doi: 10.1007/s00330-010-1807-6. Epub 2010 May 9. Eur Radiol. 2010. PMID: 20455065
-
Digital zoom of the full-field digital mammogram versus magnification mammography: a systematic review.Eur Radiol. 2020 Aug;30(8):4223-4233. doi: 10.1007/s00330-020-06798-6. Epub 2020 Mar 28. Eur Radiol. 2020. PMID: 32222798 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical