Internal versus external intrapartum foetal heart rate monitoring: the effect on linear and nonlinear parameters
- PMID: 16462016
- DOI: 10.1088/0967-3334/27/3/008
Internal versus external intrapartum foetal heart rate monitoring: the effect on linear and nonlinear parameters
Abstract
The effect of foetal heart rate (FHR) acquisition mode on linear and nonlinear parameters is still largely unknown. In 33 normal labouring women, FHR signals were acquired simultaneously by an external ultrasound sensor applied to the maternal abdomen and an internal scalp electrode, in the minutes preceding delivery. For each case, the initial and final 5, 10 and 20 min segments were analysed, considering FHR signals at a frequency of 4 Hz (the frequency at which they are transmitted by the majority of commercialized foetal monitors). Several time and frequency domain linear and nonlinear FHR indices were computed in these segments, namely mean FHR, very low frequency (VLF), low frequency (LF), high frequency (HF), approximate entropy (ApEn) and sample entropy (SampEn). Parametric confidence intervals, statistical tests and correlation coefficients were calculated in order to evaluate the effect of internal versus external FHR monitoring modes on the considered indices. The whole evaluation was repeated using FHR signals at a frequency of 2 Hz. Most time domain linear indices were similar with external and internal monitoring in the initial and final segments of the tracings. However, linear frequency domain indices were poorly correlated in the final segments and had significantly different mean values in the initial segments. Nonlinear indices were significantly different in both initial and final segments. The correlation between 4 and 2 Hz sampled parameters was high for both linear and nonlinear indices (most correlation coefficient values ranging between 0.95 and 1) but nonlinear index values were significantly higher at 2 Hz. In conclusion, the mode used to acquire FHR signals and the sampling rate employed can significantly affect most FHR indices.
Similar articles
-
Linear and nonlinear analysis of heart rate patterns associated with fetal behavioral states in the antepartum period.Early Hum Dev. 2007 Sep;83(9):585-91. doi: 10.1016/j.earlhumdev.2006.12.006. Epub 2007 Jan 29. Early Hum Dev. 2007. PMID: 17261357
-
[A new approach to quantitative electronic foetal heart-rate analysis].Z Geburtshilfe Neonatol. 2010 Jan;214(1):1-10. doi: 10.1055/s-0029-1243163. Epub 2010 Feb 12. Z Geburtshilfe Neonatol. 2010. PMID: 20155661 German.
-
Basic principles of the foetal heart rate during delivery without hypoxia and acidosis.Z Geburtshilfe Neonatol. 2012 Feb;216(1):11-21. doi: 10.1055/s-0031-1291340. Epub 2012 Feb 13. Z Geburtshilfe Neonatol. 2012. PMID: 22331523
-
Technical characteristics of current cardiotocographic monitors.Best Pract Res Clin Obstet Gynaecol. 2016 Jan;30:22-32. doi: 10.1016/j.bpobgyn.2015.05.005. Epub 2015 Jun 23. Best Pract Res Clin Obstet Gynaecol. 2016. PMID: 26206513 Review.
-
Frequency domain and entropy analysis of fetal heart rate: appealing tools for fetal surveillance and pharmacodynamic assessment of drugs.Cardiovasc Hematol Disord Drug Targets. 2008 Jun;8(2):91-8. doi: 10.2174/187152908784533720. Cardiovasc Hematol Disord Drug Targets. 2008. PMID: 18537596 Review.
Cited by
-
Similarities between maternal and fetal RR interval tachograms and their association with fetal development.Front Physiol. 2022 Nov 21;13:964755. doi: 10.3389/fphys.2022.964755. eCollection 2022. Front Physiol. 2022. PMID: 36479345 Free PMC article.
-
Non-linear Methods Predominant in Fetal Heart Rate Analysis: A Systematic Review.Front Med (Lausanne). 2021 Nov 30;8:661226. doi: 10.3389/fmed.2021.661226. eCollection 2021. Front Med (Lausanne). 2021. PMID: 34917624 Free PMC article.
-
Comparison of real beat-to-beat signals with commercially available 4 Hz sampling on the evaluation of foetal heart rate variability.Med Biol Eng Comput. 2013 Jun;51(6):665-76. doi: 10.1007/s11517-013-1036-7. Epub 2013 Jan 24. Med Biol Eng Comput. 2013. PMID: 23345009
-
Complexity of Cardiotocographic Signals as A Predictor of Labor.Entropy (Basel). 2020 Jan 16;22(1):104. doi: 10.3390/e22010104. Entropy (Basel). 2020. PMID: 33285878 Free PMC article.
-
Extracting fetal heart signals from Doppler using semi-supervised convolutional neural networks.Front Physiol. 2024 Jul 8;15:1293328. doi: 10.3389/fphys.2024.1293328. eCollection 2024. Front Physiol. 2024. PMID: 39040082 Free PMC article.