Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Apr;239(1):276-84.
doi: 10.1148/radiol.2383050167. Epub 2006 Feb 7.

Pulmonary nodules: estimation of malignancy at thin-section helical CT--effect of computer-aided diagnosis on performance of radiologists

Affiliations

Pulmonary nodules: estimation of malignancy at thin-section helical CT--effect of computer-aided diagnosis on performance of radiologists

Kazuo Awai et al. Radiology. 2006 Apr.

Abstract

Purpose: To evaluate the effect of a computer-aided diagnosis (CAD) system on the diagnostic performance of radiologists for the estimation of the malignancy of pulmonary nodules on thin-section helical computed tomographic (CT) scans.

Materials and methods: The institutional review board approved use of the CT database; informed specific study-related consent was waived. The institutional review board approved participation of radiologists; informed consent was obtained from all observers. Thirty-three (18 malignant, 15 benign) pulmonary nodules of less than 3.0 cm in maximal diameter were evaluated. Receiver operating characteristic (ROC) analysis with a continuous rating scale was used to compare observer performance for the estimation of the likelihood of malignancy first without and then with the CAD system. The participants were 10 board-certified radiologists and nine radiology residents.

Results: For all 19 participants, the mean area under the best-fit ROC curve (A(z)) values achieved without and with the CAD system were 0.843 +/- 0.097 (standard deviation) and 0.924 +/- 0.043, respectively. The difference was significant (P = .021). The mean A(z) values achieved without and with the CAD system were 0.910 +/- 0.052 and 0.944 +/- 0.040, respectively, for the 10 board-certified radiologists (P = .190) and 0.768 +/- 0.078 and 0.901 +/- 0.036, respectively, for the nine radiology residents (P = .009).

Conclusion: Use of the CAD system significantly (P = .009) improved the diagnostic performance of radiology residents for assessment of the malignancy of pulmonary nodules; however, it did not improve that of board-certified radiologists.

PubMed Disclaimer