Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Controlled Clinical Trial
. 2006 May;33(5):575-83.
doi: 10.1007/s00259-005-0015-0. Epub 2006 Feb 10.

Fully automatic diagnostic system for early- and late-onset mild Alzheimer's disease using FDG PET and 3D-SSP

Affiliations
Controlled Clinical Trial

Fully automatic diagnostic system for early- and late-onset mild Alzheimer's disease using FDG PET and 3D-SSP

Kazunari Ishii et al. Eur J Nucl Med Mol Imaging. 2006 May.

Abstract

Purpose: The purpose of this study was to design a fully automatic computer-assisted diagnostic system for early- and late-onset mild Alzheimer's disease (AD).

Methods: Glucose metabolic images were obtained from mild AD patients and normal controls using positron emission tomography (PET) and( 18)F-fluorodeoxyglucose (FDG). Two groups of 20 mild AD patients with different ages of onset were examined. A fully automatic diagnostic system using the statistical brain mapping method was established from the early-onset (EO) and late-onset (LO) groups, with mean ages of 59.1 and 70.9 years and mean MMSE scores of 23.3 and 22.8, respectively. Aged-matched normal subjects were used as controls. We compared the diagnostic performance of visual inspection of conventional axial FDG PET images by experts and beginners with that of our fully automatic diagnostic system in another 15 EO and 15 LO AD patients (mean age 58.4 and 71.7, mean MMSE 23.6 and 23.1, respectively) and 30 age-matched normal controls. A receiver operating characteristic (ROC) analysis was performed to compare data.

Results: The diagnostic performance of the automatic diagnostic system was comparable with that of visual inspection by experts. The area under the ROC curve for the automatic diagnostic system was 0.967 for EO AD patients and 0.878 for LO AD patients. The mean area under the ROC curve for visual inspection by experts was 0.863 and 0.881 for the EO and LO AD patients, respectively. The mean area under the ROC curve for visual inspection by beginners was 0.828 and 0.717, respectively.

Conclusion: The fully automatic diagnostic system for EO and LO AD was able to perform at a similar diagnostic level to visual inspection of conventional axial images by experts.

PubMed Disclaimer

References

    1. Radiology. 1996 Mar;198(3):837-43 - PubMed
    1. J Comput Assist Tomogr. 1995 Jul-Aug;19(4):541-7 - PubMed
    1. Neuroimage. 2002 Sep;17 (1):302-16 - PubMed
    1. Ann Nucl Med. 2001 Apr;15(2):85-92 - PubMed
    1. AJNR Am J Neuroradiol. 2005 Feb;26(2):333-40 - PubMed

Publication types

Substances

LinkOut - more resources