Solid-phase and bead-based cytokine immunoassay: a comparison
- PMID: 16481197
- DOI: 10.1016/j.ymeth.2005.11.008
Solid-phase and bead-based cytokine immunoassay: a comparison
Abstract
Cytokines and chemoattractive cytokines (chemokines) are present in a wide variety of body fluids such as plasma, cerebrospinal fluid, bronchoaveolar fluid, amniotic fluid, synovial fluid, middle ear effusion fluid, and urine. Cytokines can be detected using classical solid-phase sandwich immunoassays such as enzyme-linked immunosorbent assay (ELISA) or with a bead based multiplex immunoassay (MIA). The physical chemical properties of the different body fluids (such as pH and total protein content) differ, which may have an impact on the outcome of the cytokine assay. Both ELISA as well as MIA cytokine detection systems are constructed by sandwiching the protein of interest between a capture and reporter antibody. When the biological sample contains heterophilic antibodies (such as in patients with auto-immune diseases), these non-specific antibodies can cause false positive results. During pathological conditions, cytokines may be found over a wide concentration range; likewise have to cover this dynamic range in a similar fashion. The correct (statistical) analysis of standard curves and (multiplexed) data are critical for proper interpretation. Classical ELISA based cytokine assays are robust, easy to use and very well suited for measurement of single cytokines. Due to an increased interest in the integral approach to understand biological processes (the omics era), multiplex immunoassays for detection of cytokines and the interpretation of these assays are gaining popularity.
Similar articles
-
Improved multiplex immunoassay performance in human plasma and synovial fluid following removal of interfering heterophilic antibodies.J Immunol Methods. 2005 May;300(1-2):124-35. doi: 10.1016/j.jim.2005.03.009. J Immunol Methods. 2005. PMID: 15896801
-
Performance evaluation of cytometric bead assays for the measurement of lung cytokines in two rodent models.J Immunol Methods. 2008 Feb 29;331(1-2):59-68. doi: 10.1016/j.jim.2007.11.004. Epub 2007 Dec 17. J Immunol Methods. 2008. PMID: 18089291
-
Development of a bead-based multiplex assay for simultaneous quantification of cytokines in horses.Vet Immunol Immunopathol. 2009 Feb 15;127(3-4):242-8. doi: 10.1016/j.vetimm.2008.10.313. Epub 2008 Oct 18. Vet Immunol Immunopathol. 2009. PMID: 19027964
-
The immunoassay of cytokines and growth factors in biological fluids.Dev Biol Stand. 1999;97:29-37. Dev Biol Stand. 1999. PMID: 10463528 Review.
-
Inflammatory mediators of uveitis: cytokines and chemokines.Curr Opin Ophthalmol. 2006 Dec;17(6):532-7. doi: 10.1097/ICU.0b013e32801094b5. Curr Opin Ophthalmol. 2006. PMID: 17065921 Review.
Cited by
-
Ultrasensitive on-chip immunoassays with a nanoparticle-assembled photonic crystal.ACS Nano. 2012 Oct 23;6(10):8570-82. doi: 10.1021/nn301656c. Epub 2012 Sep 14. ACS Nano. 2012. PMID: 22957818 Free PMC article.
-
Prerequisites for cytokine measurements in clinical trials with multiplex immunoassays.BMC Immunol. 2009 Sep 28;10:52. doi: 10.1186/1471-2172-10-52. BMC Immunol. 2009. PMID: 19785746 Free PMC article.
-
Protein array diagnostics for guiding therapy in rheumatoid arthritis.Mol Diagn Ther. 2011 Oct 1;15(5):247-54. doi: 10.1007/BF03256416. Mol Diagn Ther. 2011. PMID: 22047152 Review.
-
Comparison of printed glycan array, suspension array and ELISA in the detection of human anti-glycan antibodies.Glycoconj J. 2011 Dec;28(8-9):507-17. doi: 10.1007/s10719-011-9349-y. Epub 2011 Sep 23. Glycoconj J. 2011. PMID: 21948103 Free PMC article.
-
Protein target quantification decision tree.Int J Proteomics. 2013;2013:701247. doi: 10.1155/2013/701247. Epub 2013 Jan 15. Int J Proteomics. 2013. PMID: 23401774 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources