Multiplex bead array assays: performance evaluation and comparison of sensitivity to ELISA
- PMID: 16481199
- PMCID: PMC1534009
- DOI: 10.1016/j.ymeth.2005.11.010
Multiplex bead array assays: performance evaluation and comparison of sensitivity to ELISA
Abstract
The measurement of soluble cytokines and other analytes in serum and plasma is becoming increasingly important in the study and management of many diseases. As a result, there is a growing demand for rapid, precise, and cost-effective measurement of such analytes in both clinical and research laboratories. Multiplex bead array assays provide quantitative measurement of large numbers of analytes using an automated 96-well plate format. Enzyme-linked immunosorbent assay (ELISAs) have long been the standard for quantitative analysis of cytokines and other biomarkers, but are not well suited for high throughput multiplex analyses. However, prior to replacement of ELISA assays with multiplex bead array assays, there is a need to know how comparable these two methods are for quantitative analyses. A number of published studies have compared these two methods and it is apparent that certain elements of these assays, such as the clones of monoclonal antibodies used for detection and reporting, are pivotal in obtaining similar results from both assays. By careful consideration of these variables, it should be possible to utilize multiplex bead array assays in lieu of ELISAs for studies requiring high throughput analysis of numerous analytes.
Similar articles
-
Performance evaluation of cytometric bead assays for the measurement of lung cytokines in two rodent models.J Immunol Methods. 2008 Feb 29;331(1-2):59-68. doi: 10.1016/j.jim.2007.11.004. Epub 2007 Dec 17. J Immunol Methods. 2008. PMID: 18089291
-
Cytometry Multiplex Bead Antibody Array.Methods Mol Biol. 2021;2237:83-92. doi: 10.1007/978-1-0716-1064-0_7. Methods Mol Biol. 2021. PMID: 33237410
-
Multiplex bead array assays for detection of soluble cytokines: comparisons of sensitivity and quantitative values among kits from multiple manufacturers.Cytometry B Clin Cytom. 2004 Sep;61(1):35-9. doi: 10.1002/cyto.b.20021. Cytometry B Clin Cytom. 2004. PMID: 15351980
-
Multiplexing molecular diagnostics and immunoassays using emerging microarray technologies.Expert Rev Mol Diagn. 2007 Jan;7(1):87-98. doi: 10.1586/14737159.7.1.87. Expert Rev Mol Diagn. 2007. PMID: 17187487 Review.
-
Cytometric bead array: a multiplexed assay platform with applications in various areas of biology.Clin Immunol. 2004 Mar;110(3):252-66. doi: 10.1016/j.clim.2003.11.017. Clin Immunol. 2004. PMID: 15047203 Review.
Cited by
-
Human cervicovaginal fluid biomarkers to predict term and preterm labor.Front Physiol. 2015 May 13;6:151. doi: 10.3389/fphys.2015.00151. eCollection 2015. Front Physiol. 2015. PMID: 26029118 Free PMC article. Review.
-
Transcription Factor Based Small-Molecule Sensing with a Rapid Cell Phone Enabled Fluorescent Bead Assay.Angew Chem Int Ed Engl. 2020 Nov 23;59(48):21597-21602. doi: 10.1002/anie.202007575. Epub 2020 Sep 18. Angew Chem Int Ed Engl. 2020. PMID: 32945589 Free PMC article.
-
Development of a highly sensitive enzyme-linked immunosorbent assay (ELISA) through use of poly-protein G-expressing cell-based microplates.Sci Rep. 2018 Dec 14;8(1):17868. doi: 10.1038/s41598-018-36192-8. Sci Rep. 2018. PMID: 30552393 Free PMC article.
-
Temporal reliability of cytokines and growth factors in EDTA plasma.BMC Res Notes. 2010 Nov 13;3:302. doi: 10.1186/1756-0500-3-302. BMC Res Notes. 2010. PMID: 21073739 Free PMC article.
-
Proinflammatory and anti-inflammatory cytokine profiles in psoriasis: use as laboratory biomarkers and disease predictors.Inflamm Res. 2019 Jul;68(7):557-567. doi: 10.1007/s00011-019-01238-8. Epub 2019 May 6. Inflamm Res. 2019. PMID: 31062065
References
-
- Horan PK, Wheeless LL. Quantitative Single Cell Analysis and Sorting. Science. 1977;198:149–157. - PubMed
-
- Copeland S, Siddiqui J, Remick D. Direct Comparison of Traditional ELISAs and Membrane Protein Arrays for Dtection and Quantification of Human Cytokines. J Immunol Meth. 2004;284:99–106. - PubMed
-
- Kellar KL, Douglass JP. Multiplexed Microsphere-based Flow Cytometric Immunoassays for Human Cytokines. J Immunol Meth. 2003;279:277–285. - PubMed
-
- Earley MC, Vogt RF, Shapiro HM, Mandy FF, Kellar KL, Bellisario R, Pass KA, Marti GE, Stewart CC, Hannon WH. Report from a Workshop on Multianalyte Microsphere Arrays. Cytometry. 2002;50:239–242. - PubMed
-
- Pang S, Smith J, Onley D, Reeve J, Walker M, Foy C. A Comparability Study of the Emerging Protein Array Platforms with Established ELISA Procedures. J Immunol Methods. 2005;302:1–12. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials