Nonpalpable breast lesions: stereotactic automated large-core biopsies
- PMID: 1648757
- DOI: 10.1148/radiology.180.2.1648757
Nonpalpable breast lesions: stereotactic automated large-core biopsies
Abstract
One hundred two patients with mammographically suspicious, nonpalpable lesions underwent stereotactic breast biopsy with a biopsy gun and an automated 14-gauge cutting needle. After biopsy, a localization wire was placed and surgical biopsy performed. There was agreement of the histologic results from the gun biopsy and the surgical biopsy specimens in 98 cases (96%), including 22 of 23 carcinomas (96%) (kappa = 0.936). The gun biopsy yielded findings that led to the correct diagnosis in two cases involving lesions that were missed at surgical biopsy; two lesions found at surgery were missed at gun biopsy. The results of this study suggest that the use of 14-gauge needles improves agreement between surgical and needle core biopsy findings and that stereotactic biopsy with an automated needle and gun can be an acceptable alternative to surgical biopsy in women with mammographically suspicious breast lesions.
Similar articles
-
Stereotactic breast biopsy with a biopsy gun.Radiology. 1990 Sep;176(3):741-7. doi: 10.1148/radiology.176.3.2167501. Radiology. 1990. PMID: 2167501
-
Core biopsy of breast lesions.J La State Med Soc. 1994 Nov;146(11):499-501. J La State Med Soc. 1994. PMID: 7806950 Clinical Trial.
-
Nonpalpable breast lesions: correlation of stereotaxic large-core needle biopsy and surgical biopsy results.Radiology. 1993 Aug;188(2):453-5. doi: 10.1148/radiology.188.2.8327696. Radiology. 1993. PMID: 8327696
-
[Recent progress in the diagnosis of nonpalpable breast lesions].Nihon Geka Gakkai Zasshi. 1996 May;97(5):343-6. Nihon Geka Gakkai Zasshi. 1996. PMID: 8709935 Review. Japanese.
-
Stereotaxic localization for fine-needle aspiration breast biopsy. Initial experience with 300 patients.Arch Surg. 1991 Sep;126(9):1137-40. doi: 10.1001/archsurg.1991.01410330099014. Arch Surg. 1991. PMID: 1656912 Review.
Cited by
-
Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis.Br J Cancer. 2000 Mar;82(5):1017-21. doi: 10.1054/bjoc.1999.1036. Br J Cancer. 2000. PMID: 10737383 Free PMC article.
-
Can galactography-guided stereotactic, 11-gauge, vacuum-assisted breast biopsy of intraductal lesions serve as an alternative to surgical biopsy?Eur Radiol. 2009 Dec;19(12):2878-85. doi: 10.1007/s00330-009-1502-7. Eur Radiol. 2009. PMID: 19565246
-
The clinical utility of a adding lateral approach to conventional vertical approach for prone stereotactic vacuum-assisted breast biopsy.Korean J Radiol. 2013 Jul-Aug;14(4):568-75. doi: 10.3348/kjr.2013.14.4.568. Epub 2013 Jul 17. Korean J Radiol. 2013. PMID: 23901313 Free PMC article.
-
Effectiveness of the diagnostic pathway of BLES: could it be safely used as a therapeutic method in selected benign lesions?Diagn Interv Radiol. 2019 Nov;25(6):428-434. doi: 10.5152/dir.2019.18427. Diagn Interv Radiol. 2019. PMID: 31650964 Free PMC article.
-
Surgical biopsy findings in patients with atypical hyperplasia diagnosed by stereotaxic core needle biopsy.Ann Surg Oncol. 1996 Sep;3(5):483-8. doi: 10.1007/BF02305767. Ann Surg Oncol. 1996. PMID: 8876891
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical