Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2006 Jan-Feb;20(1):83-96.
doi: 10.1892/0891-6640(2006)20[83:ialoot]2.0.co;2.

Immediate and late outcomes of transarterial coil occlusion of patent ductus arteriosus in dogs

Affiliations
Free article
Clinical Trial

Immediate and late outcomes of transarterial coil occlusion of patent ductus arteriosus in dogs

F E Campbell et al. J Vet Intern Med. 2006 Jan-Feb.
Free article

Abstract

Records from dogs (n = 125) that underwent attempted transarterial coil occlusion of patent ductus arteriosus (PDA) at the University of California, Davis, between 1998 and 2003, were reviewed, and a subset of these dogs (n = 31) in which the procedure was performed at least 12 months earlier were reexamined to determine long-term outcome. Coil implantation was achieved in 108 dogs (86%). Despite immediate complete ductal closure in only 34% of dogs, the procedure was hemodynamically successful as evidenced by a reduction in indexed left ventricular internal diameter in diastole (LVIDd; P < .0001), fractional shortening (P < .0001), and left atrial to aortic ratio (LA: Ao; P = .022) within 24 hours. Complete ductal closure was documented in 61% of dogs examined 12 to 63 months after coil occlusion. Long-standing residual ductal flow in the other 39% of dogs was not associated with increased indexed LVIDd or LA: Ao and was not hemodynamically relevant. Repeat intervention was deemed advisable in only 4 dogs with persistent (n = 1) or recurrent (n = 3) ductal flow. Complications included aberrant embolization (n = 27), death (n = 3), ductal reopening (n = 3), transient hemoglobinuria (n = 2), hemorrhage (n = 1), aberrant coil placement (n = 1), pulmonary hypertension (n = 1), and skin abscessation (n = 1). Serious infectious complications did not occur despite antibiotic administration to only 40% of these dogs. Transarterial coil occlusion was not possible in 14 dogs (11%) because of coil instability in the PDA and was associated with increased indexed minimum ductal diameter (P = .03), LVIDd (P = .0002), LVIDs (P = 0.001), and congestive left heart failure (P = .03) reflecting a relatively large shunt volume.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources