Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 May 25;109(1-2):151-6.
doi: 10.1016/j.ijfoodmicro.2006.01.010. Epub 2006 Feb 23.

Immunoconcentration of Shiga toxin-producing Escherichia coli O157 from animal faeces and raw meats by using Dynabeads anti-E. coli O157 and the VIDAS system

Affiliations
Comparative Study

Immunoconcentration of Shiga toxin-producing Escherichia coli O157 from animal faeces and raw meats by using Dynabeads anti-E. coli O157 and the VIDAS system

M Aminul Islam et al. Int J Food Microbiol. .

Abstract

To identify the reservoirs and routes of transmission of Shiga toxin-producing Escherichia coli (STEC) O157, sensitive detection and isolation methods are necessary. The sensitivity of traditional culture methods can be improved significantly by the inclusion of an immunoconcentration step, resulting in less false-negatives. In this report, we evaluated the results of two commercially available test systems: Dynabeads anti-E. coli O157 and the Vitek Immunodiagnostic Assay System (VIDAS) Immuno-Concentration E. coli O157 (ICE) kit. Additionally, we compared two selective isolation media for STEC O157. Statistical analysis of the results obtained for animal faecal samples (n=637) examined by both immunoconcentration methods showed that by the manual Dynabeads anti-E. coli O157 procedure systematically more samples were identified as positive than by the VIDAS ICE. In case of meat samples (n=360), no difference between the results of the two methods was found. In addition to being accurate, the Dynabeads anti-E. coli O157 method is a less expensive method than the VIDAS ICE. But, the Dynabeads method is laborious and there is a risk of cross-contamination. The VIDAS ICE procedure on the other hand is fully automated with a standardised performance; fast and safe for the user. Irrespective of the type of sample (faeces or meat) and the immunoconcentration technique applied (Dynabeads anti-E. coli O157 or VIDAS ICE) more samples were found positive after plating onto CHROMagar O157 with cefixime (0.025 mg l(-1)) and tellurite (1.25 mg l(-1)) than after plating onto sorbitol-MacConkey agar with cefixime (0.05 mg l(-1)) and tellurite (2.5 mg l(-1)). However, only in case of meat samples examined by the VIDAS ICE the difference between the isolation media was not statistically significant.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources