Radiological evaluation of the metal-bone interface of a porous tantalum monoblock acetabular component
- PMID: 16498001
- DOI: 10.1302/0301-620X.88B3.16940
Radiological evaluation of the metal-bone interface of a porous tantalum monoblock acetabular component
Abstract
Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a gap between the outer surface of the component and the acetabular host bed which ranged from 1 to 5 mm. All patients were followed up clinically and radiologically for a mean of 7.3 years (7 to 7.5). The 25 hips with the 1 to 5 mm gaps were studied for component migration at two years using the Einzel-Bild-Roentgen-Analyse (EBRA) digital measurement method. At 24 weeks all the post-operative gaps were filled with bone and no acetabular component had migrated. The radiographic outcome of all 86 components showed no radiolucent lines and no evidence of lysis. No acetabular implant was revised. There were no dislocations or other complications. The bridging of the interface gaps (up to 5 mm) by the trabecular metal monoblock acetabular component indicates the strong osteoconductive, and possibly osteoinductive, properties of trabecular metal.
Similar articles
-
The Trabecular Metal Monoblock acetabular component in patients with high congenital hip dislocation: a prospective study.J Bone Joint Surg Br. 2010 May;92(5):624-8. doi: 10.1302/0301-620X.92B5.23256. J Bone Joint Surg Br. 2010. PMID: 20435996
-
Eight- to ten-year clinical and radiographic outcome of a porous tantalum monoblock acetabular component.J Arthroplasty. 2009 Aug;24(5):705-9. doi: 10.1016/j.arth.2008.06.020. Epub 2008 Aug 13. J Arthroplasty. 2009. PMID: 18703310
-
Long-Term Clinical and Radiographic Outcomes of Porous Tantalum Monoblock Acetabular Component in Primary Hip Arthroplasty: A Minimum of 15-Year Follow-Up.J Arthroplasty. 2016 Sep;31(9 Suppl):110-4. doi: 10.1016/j.arth.2015.12.020. Epub 2015 Dec 17. J Arthroplasty. 2016. PMID: 26781387
-
Hip arthroplasty. Part 2: normal and abnormal radiographic findings.Clin Radiol. 2009 Oct;64(10):961-71. doi: 10.1016/j.crad.2009.05.002. Epub 2009 Jun 16. Clin Radiol. 2009. PMID: 19748001 Review.
-
Applications of porous tantalum in total hip arthroplasty.J Am Acad Orthop Surg. 2006 Nov;14(12):646-55. doi: 10.5435/00124635-200611000-00008. J Am Acad Orthop Surg. 2006. PMID: 17077337 Review.
Cited by
-
Tantalum as Trabecular Metal for Endosseous Implantable Applications.Biomimetics (Basel). 2023 Jan 23;8(1):49. doi: 10.3390/biomimetics8010049. Biomimetics (Basel). 2023. PMID: 36810380 Free PMC article. Review.
-
Analysis of bone ingrowth on a tantalum cup.Indian J Orthop. 2008 Jul;42(3):275-8. doi: 10.4103/0019-5413.39553. Indian J Orthop. 2008. PMID: 19753152 Free PMC article.
-
Revision arthroplasty: an update.Skeletal Radiol. 2009 Nov;38(11):1031-6. doi: 10.1007/s00256-009-0781-z. Skeletal Radiol. 2009. PMID: 19701811 Review. No abstract available.
-
A monoblock porous tantalum acetabular cup has no osteolysis on CT at 10 years.Clin Orthop Relat Res. 2011 Feb;469(2):382-6. doi: 10.1007/s11999-010-1500-8. Clin Orthop Relat Res. 2011. PMID: 20809172 Free PMC article.
-
Multicentre use of a porous tantalum monoblock acetabular component.Int Orthop. 2009 Aug;33(4):911-6. doi: 10.1007/s00264-008-0581-4. Epub 2008 May 29. Int Orthop. 2009. PMID: 18509638 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous