Today, many options are available for the correction of presbyopia. New technology perpetually surfaces to offer better ideas and designs to meet the visual demands of the presbyopic population. This article provides information on various modalities for spectacle and contact lens correction of presbyopia. It is based on current information at the time of publication and is not intended to be a fitting guide.
Similar articles
-
BCLA CLEAR Presbyopia: Management with contact lenses and spectacles.Cont Lens Anterior Eye. 2024 Aug;47(4):102158. doi: 10.1016/j.clae.2024.102158. Epub 2024 Apr 16. Cont Lens Anterior Eye. 2024. PMID: 38631935 Review.
-
Comparison between "readables" aspheric spectacle lenses and conventional spherical spectacle lenses for overcorrection of presbyopic single-vision contact lens wearers.J Am Optom Assoc. 1993 Mar;64(3):206-9. J Am Optom Assoc. 1993. PMID: 8454839 Clinical Trial.
-
Visual performance of subjects wearing presbyopic contact lenses.Optom Vis Sci. 2006 Aug;83(8):611-5. doi: 10.1097/01.opx.0000232185.00091.45. Optom Vis Sci. 2006. PMID: 16909087
-
Developments in the correction of presbyopia I: spectacle and contact lenses.Ophthalmic Physiol Opt. 2014 Jan;34(1):8-29. doi: 10.1111/opo.12091. Epub 2013 Nov 10. Ophthalmic Physiol Opt. 2014. PMID: 24205890 Review.
-
[Bifocal contact lenses as a correction method in presbyopia].Vestn Oftalmol. 2003 Jul-Aug;119(4):28-31. Vestn Oftalmol. 2003. PMID: 12934502 Russian.
Cited by
-
The VEPRO trial: a cross-over randomised controlled trial comparing 2 progressive lenses for patients with presbyopia.Trials. 2008 Sep 19;9:54. doi: 10.1186/1745-6215-9-54. Trials. 2008. PMID: 18803826 Free PMC article.
-
Correlation between Tribological Properties and the Quantified Structural Changes of Lysozyme on Poly (2-hydroxyethyl methacrylate) Contact Lens.Polymers (Basel). 2020 Jul 23;12(8):1639. doi: 10.3390/polym12081639. Polymers (Basel). 2020. PMID: 32717989 Free PMC article.
-
Creep deformation in elastomeric membranes of liquid-filled tunable-focus lenses.Appl Opt. 2019 Aug 10;58(23):6446-6454. doi: 10.1364/AO.58.006446. Appl Opt. 2019. PMID: 31503794 Free PMC article.
-
Pharmacological Treatment of Presbyopia Using Pilocarpine 1.25% Eye Drops.J Ophthalmic Vis Res. 2024 Dec 31;19(4):468-475. doi: 10.18502/jovr.v19i4.14578. eCollection 2024 Dec. J Ophthalmic Vis Res. 2024. PMID: 39917455 Free PMC article.
-
Tunable-focus lens for adaptive eyeglasses.Opt Express. 2017 Jan 23;25(2):1221-1233. doi: 10.1364/OE.25.001221. Opt Express. 2017. PMID: 28158006 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical