Press fit fixation of cementless cups: how much stability do we need indeed?
- PMID: 16501986
- DOI: 10.1007/s00402-005-0001-9
Press fit fixation of cementless cups: how much stability do we need indeed?
Abstract
Introduction: Using screws for a better primary and secondary fixation has been discussed in the literature of the recent years, although the principle of press fit has been explained as the principle of a push-button. The authors wanted to compare their own results in patients using X-rays from the postoperative course to decide if it is really safer to use screws or not.
Materials and methods: Two hundred and twenty one consecutive, not selected patients were treated with total hip arthroplasty using a cementless cup type Duraloc. They were followed up over a time of 5 years for radiological changes of the bony acetabulum around the cup ("acetabular zones" according to De Lee and Charnley). One hundred and ten cups were additionally fixed with one to three screws at the upper part in region C1, 101 cups were implanted without the use of screws.
Results: Periprosthetic changes visible on the radiographs (immediate postoperative gaps, subsequent sclerosis and radiolucent lines) were assessed according to the time of their appearance. A gap in zone C2 was seen more often immediately after operation within the group without screws (17.8% vs. 7.3%) and disappeared within the following 25 months. Within the group with screws significantly more often a gap was found in zone C1 and C3 compared to the group without screws (7.3% vs. 1.9%). In the group with screws a sclerosis of the bone in zone C1 developed in 32.7% mostly within the first 5 months. It was followed by a radiolucent line in zone C3 in 28.2% mainly within 5-25 months postoperatively and in zone C1 in 20.9% within 16 months. Significantly less seldom were these phenomena seen at the cups without screw fixation. There was no correlation between lateral or medial positioning and deviations from the ideal inclination to the bony changes around the cups. No signs of loosening occurred in either group.
Conclusion: Less radiological changes around the cup if no screws were used and no disadvantages within this group led to the conclusion that an additional screw fixation in principle is not necessary in press-fit cups.
Similar articles
-
[Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].Acta Chir Orthop Traumatol Cech. 2002;69(1):8-15. Acta Chir Orthop Traumatol Cech. 2002. PMID: 11951572 German.
-
High migration rate of two types of threaded acetabular cups.Arch Orthop Trauma Surg. 2004 Jan;124(1):17-25. doi: 10.1007/s00402-003-0592-y. Epub 2003 Oct 29. Arch Orthop Trauma Surg. 2004. PMID: 14586628
-
Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.Arch Orthop Trauma Surg. 2008 Dec;128(12):1379-86. doi: 10.1007/s00402-008-0731-6. Epub 2008 Aug 30. Arch Orthop Trauma Surg. 2008. PMID: 18758793
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
-
Are additional screws required for press-fit fixation of cementless acetabular cups? A systematic review and meta-analysis.J Orthop Traumatol. 2022 Feb 10;23(1):9. doi: 10.1186/s10195-022-00629-8. J Orthop Traumatol. 2022. PMID: 35142933 Free PMC article.
Cited by
-
Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty.Eur J Med Res. 2011 Mar 28;16(3):127-32. doi: 10.1186/2047-783x-16-3-127. Eur J Med Res. 2011. PMID: 21486725 Free PMC article.
-
A cementless, elastic press-fit socket with and without screws.Acta Orthop. 2012 Oct;83(5):481-7. doi: 10.3109/17453674.2012.720116. Acta Orthop. 2012. PMID: 23083434 Free PMC article. Clinical Trial.
-
Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.Clin Orthop Relat Res. 2012 Nov;470(11):3014-23. doi: 10.1007/s11999-012-2381-9. Clin Orthop Relat Res. 2012. PMID: 22576930 Free PMC article.
-
Relationship between use of screws and acetabular cup stability in total hip arthroplasty: a meta-analysis.J Int Med Res. 2020 Feb;48(2):300060520903649. doi: 10.1177/0300060520903649. J Int Med Res. 2020. PMID: 32054354 Free PMC article.
-
The use of acetabular screws in total hip arthroplasty and its influence on wear and periacetabular osteolysis in the long-term follow-up.Int Orthop. 2022 Apr;46(4):717-722. doi: 10.1007/s00264-021-05219-7. Epub 2021 Sep 28. Int Orthop. 2022. PMID: 34581866 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous