. 2006 Oct;20(10):1043-8.
doi: 10.1002/bmc.635.

Simultaneous estimation of six anti-diabetic drugs--glibenclamide, gliclazide, glipizide, pioglitazone, repaglinide and rosiglitazone: development of a novel HPLC method for use in the analysis of pharmaceutical formulations and its application to human plasma assay

Affiliations

Simultaneous estimation of six anti-diabetic drugs--glibenclamide, gliclazide, glipizide, pioglitazone, repaglinide and rosiglitazone: development of a novel HPLC method for use in the analysis of pharmaceutical formulations and its application to human plasma assay

P Venkatesh et al. Biomed Chromatogr. 2006 Oct.

Abstract

This paper describes a convenient method for the separation and simultaneous determination of six anti-diabetic drugs viz., glibenclamide (GLB), gliclazide (GLC), glipizide (GLZ), pioglitazone (PGL), repaglinide (RPG) and rosiglitazone (RGL) in pharmaceutical formulations. Also, the assay has been shown applied to support quantification of the six anti-diabetic drugs in human plasma. The analytes were either injected directly onto the column after suitable dilution (pharmaceutical formulation analysis) or a simple extraction procedure, using acetonitrile, from human plasma spiked with anti-diabetic drugs and internal standard (IS). Ternary gradient elution at a flow rate of 1 mL/min was employed on an Intertisl ODS 3V column (4.6 x 250 mm, 5 microm) at ambient temperature. The mobile phase consisted of 0.01 m formic acid (pH 3.0), acetonitrile, Milli Q water and methanol. Celecoxib was used as an IS. The six anti-diabetic drugs were monitored at a wavelength of 260 nm. The nominal retention times of RGL, PGL, GLZ, GLC, GLB, IS and RGL were 11.4, 13.3, 14.8, 17.6, 20.78, 22.1 and 25.4 min, respectively. The assay developed for formulation analysis was found to be accurate and precise. The calibration curves ranged from 0.1 to 100 microg/mL for all analytes with the exception of GLB, where the range was 0.3-100 microg/mL. The plasma assay was validated for parameters such as specificity, accuracy and extraction recovery. The proposed method is simple, selective and can be extended for routine analysis of anti-diabetics in pharmaceutical preparations and in biological matrices.