Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2006 Feb;4(2):98-105.
doi: 10.3171/spi.2006.4.2.98.

Complications with cervical arthroplasty

Affiliations
Clinical Trial

Complications with cervical arthroplasty

Gwynedd E Pickett et al. J Neurosurg Spine. 2006 Feb.

Abstract

Object: Spinal arthroplasty is becoming more widely performed in the treatment of degenerative cervical disc disease. Although this new technology may offer benefits over arthrodesis, it also requires that the surgeon acquire new operative techniques, and new potential complications are introduced. To determine the incidence and distribution of perioperative complications, the authors analyzed their early data obtained in a series of patients treated with the Bryan Cervical Disc prosthesis.

Methods: The authors prospectively recorded operative data, complications, and clinical and radiographic outcome data in all patients treated with Bryan prosthesis-based arthroplasty at two tertiary care centers since 2001. Patients underwent standard anterior cervical discectomy followed by one- to three-level arthroplasty. Ninety-six discs were implanted in 74 patients. The perioperative complication rate was 6.2% per treated level. In one patient a retropharyngeal hematoma developed, requiring evacuation. Neurological worsening occurred in three patients. Intraoperative migration of the prosthesis was observed in one two-level case, whereas delayed migration occurred in one patient with postoperative segmental kyphosis. In another patient with severe postoperative segmental kyphosis, revision was required with a customized lordotic prosthesis. Heterotopic ossification and spontaneous fusion occurred in two cases; motion was preserved in the remaining 94 prostheses. Partial dislocation of the prosthesis in extension occurred in one patient with preoperative segmental hypermobility, the first reported failure of a Bryan prosthesis. Twenty-five percent of patients reported neck and shoulder pain during the late follow-up period. There was a trend toward increased kyphosis of the C2-7 curvature postoperatively.

Conclusions: The Bryan prosthesis was effective in maintaining spinal motion. Major perioperative and device-related complications were infrequent.