Integrated positron emission tomography and magnetic resonance imaging-guided resection of brain tumors: a report of 103 consecutive procedures
- PMID: 16509498
- DOI: 10.3171/jns.2006.104.2.238
Integrated positron emission tomography and magnetic resonance imaging-guided resection of brain tumors: a report of 103 consecutive procedures
Abstract
Object: The aim of this study was to evaluate the integration of positron emission tomography (PET) scanning data into the image-guided resection of brain tumors.
Methods: Positron emission tomography scans obtained using fluorine-18 fluorodeoxyglucose (FDG) and L-[methyl-11C]methionine (MET) were combined with magnetic resonance (MR) images in the navigational planning of 103 resections of brain tumors (63 low-grade gliomas [LGGs] and 40 high-grade gliomas [HGGs]). These procedures were performed in 91 patients (57 males and 34 females) in whom tumor boundaries could not be accurately identified on MR images for navigation-based resection. The level and distribution of PET tracer uptake in the tumor were analyzed to define the lesion contours, which in turn yielded a PET volume. The PET scanning-demonstrated lesion volume was subsequently projected onto MR images and compared with MR imaging data (MR volume) to define a final target volume for navigation-based resection-the tumor contours were displayed in the microscope's eyepiece. Maximal tumor resection was accomplished in each case, with the intention of removing the entire area of abnormal metabolic activity visualized during surgical planning. Early postoperative MR imaging and PET scanning studies were performed to assess the quality of tumor resection. Both pre- and postoperative analyses of MR and PET images revealed whether integrating PET data into the navigational planning contributed to improved tumor volume definition and tumor resection. Metabolic information on tumor heterogeneity or extent was useful in planning the surgery. In 83 (80%) of 103 procedures, PET studies contributed to defining a final target volume different from that obtained with MR imaging alone. Furthermore, FDG-PET scanning, which was performed in a majority of HGG cases, showed that PET volume was less extended than the MR volume in 16 of 21 cases and contributed to targeting the resection to the hypermetabolic (anaplastic) area in 11 (69%) of 16 cases. Performed in 59 LGG cases and 23 HGG cases, MET-PET demonstrated that the PET volume did not match the MR volume and improved the tumor volume definition in 52 (88%) of 59 and 18 (78%) of 23, respectively. Total resection of the area of increased PET tracer uptake was achieved in 54 (52%) of 103 procedures.
Conclusions: Imaging guidance with PET scanning provided independent and complementary information that helped to assess tumor extent and plan tumor resection better than with MR imaging guidance alone. The PET scanning guidance could help increase the amount of tumor removed and target image-guided resection to tumor portions that represent the highest evolving potential.
Similar articles
-
Positron emission tomography-guided volumetric resection of supratentorial high-grade gliomas: a survival analysis in 66 consecutive patients.Neurosurgery. 2009 Mar;64(3):471-81; discussion 481. doi: 10.1227/01.NEU.0000338949.94496.85. Neurosurgery. 2009. PMID: 19240609 Clinical Trial.
-
Clinical impact of integrating positron emission tomography during surgery in 85 children with brain tumors.J Neurosurg Pediatr. 2010 May;5(5):486-99. doi: 10.3171/2010.1.PEDS09481. J Neurosurg Pediatr. 2010. PMID: 20433263
-
Integration of [11C]methionine-positron emission tomographic and magnetic resonance imaging for image-guided surgical resection of infiltrative low-grade brain tumors in children.Neurosurgery. 2005 Jul;57(1 Suppl):128-39; discussion 128-39. doi: 10.1227/01.neu.0000163598.59870.6d. Neurosurgery. 2005. PMID: 15987579 Clinical Trial.
-
Positron emission tomography for radiation treatment planning.Strahlenther Onkol. 2005 Aug;181(8):483-99. doi: 10.1007/s00066-005-1422-7. Strahlenther Onkol. 2005. PMID: 16044216 Review.
-
The integration of metabolic imaging in stereotactic procedures including radiosurgery: a review.J Neurosurg. 2002 Dec;97(5 Suppl):542-50. doi: 10.3171/jns.2002.97.supplement. J Neurosurg. 2002. PMID: 12507094 Review.
Cited by
-
A Systematic Review of Amino Acid PET Imaging in Adult-Type High-Grade Glioma Surgery: A Neurosurgeon's Perspective.Cancers (Basel). 2022 Dec 23;15(1):90. doi: 10.3390/cancers15010090. Cancers (Basel). 2022. PMID: 36612085 Free PMC article. Review.
-
Current trends in the surgical management and treatment of adult glioblastoma.Ann Transl Med. 2015 Jun;3(9):121. doi: 10.3978/j.issn.2305-5839.2015.05.10. Ann Transl Med. 2015. PMID: 26207249 Free PMC article. Review.
-
Current status and future role of brain PET/MRI in clinical and research settings.Eur J Nucl Med Mol Imaging. 2015 Mar;42(3):512-26. doi: 10.1007/s00259-014-2970-9. Epub 2015 Jan 9. Eur J Nucl Med Mol Imaging. 2015. PMID: 25573629 Review.
-
Influence of region-of-interest designs on quantitative measurement of multimodal imaging of MR non-enhancing gliomas.Oncol Lett. 2018 May;15(5):7934-7940. doi: 10.3892/ol.2018.8319. Epub 2018 Mar 22. Oncol Lett. 2018. PMID: 29725480 Free PMC article.
-
Failure pattern following complete resection plus radiotherapy and temozolomide is at the resection margin in patients with glioblastoma.J Neurooncol. 2013 Jan;111(1):19-23. doi: 10.1007/s11060-012-0983-4. Epub 2012 Oct 10. J Neurooncol. 2013. PMID: 23054563
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous