Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Feb;26(1):9-17.

Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels

  • PMID: 16515092

Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels

Richard J Lazzara et al. Int J Periodontics Restorative Dent. 2006 Feb.

Abstract

Histologic and radiographic observations suggest that a biologic dimension of hard and soft tissues exists around dental implants and extends apically from the implant-abutment interface. Radiographic evidence of the development of the biologic dimension can be demonstrated by the vertical repositioning of crestal bone and the subsequent soft tissue attachment to the implant that occurs when an implant is uncovered and exposed to the oral environment and matching-diameter restorative components are attached. Historically, two-piece dental implant systems have been restored with prosthetic components that locate the interface between the implant and the attached component element at the outer edge of the implant platform. In 1991, Implant Innovations introduced wide-diameter implants with matching wide-diameter platforms. When introduced, however, matching-diameter prosthetic components were not available, and many of the early 5.0- and 6.0-mm-wide implants received "standard"-diameter (4.1-mm) healing abutments and were restored with "standard"-diameter (4.1-mm) prosthetic components. Long-term radiographic follow-up of these "platform-switched" restored wide-diameter dental implants has demonstrated a smaller than expected vertical change in the crestal bone height around these implants than is typically observed around implants restored conventionally with prosthetic components of matching diameters. This radiographic observation suggests that the resulting postrestorative biologic process resulting in the loss of crestal bone height is altered when the outer edge of the implant-abutment interface is horizontally repositioned inwardly and away from the outer edge of the implant platform. This article introduces the concept of platform switching and provides a foundation for future development of the biologic understanding of the observed radiographic findings and clinical rationale for this technique.

PubMed Disclaimer

Substances

LinkOut - more resources