Calibration and field performance of membrane-enclosed sorptive coating for integrative passive sampling of persistent organic pollutants in water
- PMID: 16516361
- DOI: 10.1016/j.envpol.2005.11.046
Calibration and field performance of membrane-enclosed sorptive coating for integrative passive sampling of persistent organic pollutants in water
Abstract
Membrane-enclosed sorptive coating (MESCO) is a miniaturised monitoring device that enables integrative passive sampling of persistent, hydrophobic organic pollutants in water. The system combines the passive sampling with solventless preconcentration of organic pollutants from water and subsequent desorption of analytes on-line into a chromatographic system. Exchange kinetics of chemicals between water and MESCO was studied at different flow rates of water, in order to characterize the effect of variable environmental conditions on the sampler performance, and to identify a method for in situ correction of the laboratory-derived calibration data. It was found that the desorption of chemicals from MESCO into water is isotropic to the absorption of the analytes onto the sampler under the same exposure conditions. This allows for the in situ calibration of the uptake of pollutants using elimination kinetics of performance reference compounds and more accurate estimates of target analyte concentrations. A field study was conducted to test the sampler performance alongside spot sampling. A good agreement of contaminant patterns and water concentrations was obtained by the two sampling techniques.
Similar articles
-
Modelling and field application of the Chemcatcher passive sampler calibration data for the monitoring of hydrophobic organic pollutants in water.Environ Pollut. 2007 Feb;145(3):895-904. doi: 10.1016/j.envpol.2006.04.030. Epub 2006 Aug 21. Environ Pollut. 2007. PMID: 16920239
-
Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water.Environ Pollut. 2012 May;164:158-63. doi: 10.1016/j.envpol.2012.01.013. Epub 2012 Feb 21. Environ Pollut. 2012. PMID: 22361054
-
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water.Environ Pollut. 2006 Jul;142(2):333-43. doi: 10.1016/j.envpol.2005.10.033. Epub 2005 Dec 15. Environ Pollut. 2006. PMID: 16343715
-
Configurations and calibration methods for passive sampling techniques.J Chromatogr A. 2007 Oct 19;1168(1-2):226-35; discussion 225. doi: 10.1016/j.chroma.2007.01.133. Epub 2007 Feb 7. J Chromatogr A. 2007. PMID: 17449049 Review.
-
Review of atrazine sampling by polar organic chemical integrative samplers and Chemcatcher.Environ Toxicol Chem. 2018 Jul;37(7):1786-1798. doi: 10.1002/etc.4160. Epub 2018 Jun 7. Environ Toxicol Chem. 2018. PMID: 29687480 Review.
Cited by
-
Application of the triolein-embedded cellulose acetate membrane passive sampler for monitoring of polycyclic aromatic hydrocarbons in water.Environ Sci Pollut Res Int. 2014;21(16):9852-60. doi: 10.1007/s11356-014-2989-2. Epub 2014 May 27. Environ Sci Pollut Res Int. 2014. PMID: 24859695
-
Integrated methodology for assessing the HCH groundwater pollution at the multi-source contaminated mega-site Bitterfeld/Wolfen.Environ Sci Pollut Res Int. 2013 Apr;20(4):1907-17. doi: 10.1007/s11356-012-0963-4. Epub 2013 Mar 27. Environ Sci Pollut Res Int. 2013. PMID: 23532510
-
Passive sampling of selected pesticides in aquatic environment using polar organic chemical integrative samplers.Environ Sci Pollut Res Int. 2011 Aug;18(7):1222-33. doi: 10.1007/s11356-010-0436-6. Epub 2011 Mar 4. Environ Sci Pollut Res Int. 2011. PMID: 21373860
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources