Protein folding mechanisms studied by time-resolved electrospray mass spectrometry
- PMID: 16526400
- DOI: 10.2144/06402TE01
Protein folding mechanisms studied by time-resolved electrospray mass spectrometry
Similar articles
-
Equilibrium and kinetic folding of rabbit muscle triosephosphate isomerase by hydrogen exchange mass spectrometry.J Mol Biol. 2004 Mar 5;336(5):1251-63. doi: 10.1016/j.jmb.2003.12.076. J Mol Biol. 2004. PMID: 15037083
-
Folding kinetics of the S100A11 protein dimer studied by time-resolved electrospray mass spectrometry and pulsed hydrogen-deuterium exchange.Biochemistry. 2006 Mar 7;45(9):3005-13. doi: 10.1021/bi052349a. Biochemistry. 2006. PMID: 16503655
-
Evidence for unfolding and refolding of gas-phase cytochrome C ions in a Paul trap.J Am Soc Mass Spectrom. 2005 Sep;16(9):1493-1497. doi: 10.1016/j.jasms.2005.04.013. J Am Soc Mass Spectrom. 2005. PMID: 16019223
-
Protein analysis by hydrogen exchange mass spectrometry.Annu Rev Biophys Biomol Struct. 2003;32:1-25. doi: 10.1146/annurev.biophys.32.110601.142417. Epub 2003 Feb 18. Annu Rev Biophys Biomol Struct. 2003. PMID: 12598366 Review.
-
Conformational effects in protein electrospray-ionization mass spectrometry.Mass Spectrom Rev. 2016 Jan-Feb;35(1):111-22. doi: 10.1002/mas.21465. Epub 2015 May 7. Mass Spectrom Rev. 2016. PMID: 25952139 Review.
Cited by
-
The role of initial oligomers in amyloid fibril formation by human stefin B.Int J Mol Sci. 2013 Sep 5;14(9):18362-84. doi: 10.3390/ijms140918362. Int J Mol Sci. 2013. PMID: 24013380 Free PMC article.
-
Dimerization of the type IV pilin from Pseudomonas aeruginosa strain K122-4 results in increased helix stability as measured by time-resolved hydrogen-deuterium exchange.Struct Dyn. 2015 Aug 28;3(1):012001. doi: 10.1063/1.4929597. eCollection 2016 Jan. Struct Dyn. 2015. PMID: 26798830 Free PMC article.
-
Analysis of the kinetics of folding of proteins and peptides using circular dichroism.Nat Protoc. 2006;1(6):2891-9. doi: 10.1038/nprot.2006.244. Nat Protoc. 2006. PMID: 17406548 Free PMC article.
-
A versatile microfluidic chip for millisecond time-scale kinetic studies by electrospray mass spectrometry.J Am Soc Mass Spectrom. 2009 Jan;20(1):124-30. doi: 10.1016/j.jasms.2008.09.005. Epub 2008 Sep 7. J Am Soc Mass Spectrom. 2009. PMID: 18845447
-
Vapor treatment of electrospray droplets: evidence for the folding of initially denatured proteins on the sub-millisecond time-scale.J Am Soc Mass Spectrom. 2012 Jan;23(1):88-101. doi: 10.1007/s13361-011-0258-x. Epub 2011 Oct 21. J Am Soc Mass Spectrom. 2012. PMID: 22016004
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources