Vector-based spatial-temporal minimum L1-norm solution for MEG
- PMID: 16542857
- DOI: 10.1016/j.neuroimage.2006.01.029
Vector-based spatial-temporal minimum L1-norm solution for MEG
Abstract
Minimum L1-norm solutions have been used by many investigators to analyze MEG responses because they provide high spatial resolution images. However, conventional minimum L1-norm approaches suffer from instability in spatial construction, and poor smoothness of the reconstructed source time-courses. Activity commonly "jumps" from one grid point to (usually) the neighboring grid points. Equivalently, the time-course of one specific grid point can show substantial "spiky-looking" discontinuity. In the present study, we present a new vector-based spatial-temporal analysis using a L1-minimum-norm (VESTAL). This approach is based on a principle of MEG physics: the magnetic waveforms in sensor-space are linear functions of the source time-courses in the imaging-space. Our computer simulations showed that VESTAL provides good reconstruction of the source amplitude and orientation, with high stability and resolution in both the spatial and temporal domains. "Spiky-looking" discontinuity was not observed in the source time-courses. Importantly, the simulations also showed that VESTAL can resolve sources that are 100% correlated. We then examined the performance of VESTAL in the analysis of human median-nerve MEG responses. The results demonstrated that this method easily distinguishes sources very spatially close to each other, including individual primary somatosensory areas (BA 1, 2, 3b), primary motor area (BA 4), and other regions in the somatosensory system (e.g., BA 5, 7, SII, SMA, and temporal-parietal junction) with high temporal stability and resolution. VESTAL's potential for obtaining information on source extent was also examined.
Similar articles
-
MEG source imaging method using fast L1 minimum-norm and its applications to signals with brain noise and human resting-state source amplitude images.Neuroimage. 2014 Jan 1;84:585-604. doi: 10.1016/j.neuroimage.2013.09.022. Epub 2013 Sep 19. Neuroimage. 2014. PMID: 24055704 Free PMC article.
-
Assessing and improving the spatial accuracy in MEG source localization by depth-weighted minimum-norm estimates.Neuroimage. 2006 May 15;31(1):160-71. doi: 10.1016/j.neuroimage.2005.11.054. Epub 2006 Mar 6. Neuroimage. 2006. PMID: 16520063
-
Spatiotemporal imaging of electrical activity related to attention to somatosensory stimulation.Neuroimage. 2002 Nov;17(3):1347-57. doi: 10.1006/nimg.2002.1222. Neuroimage. 2002. PMID: 12414274
-
[Investigation of the Cerebral Cortex Using Magnetoencephalography(MEG)].Brain Nerve. 2015 Apr;67(4):451-66. doi: 10.11477/mf.1416200162. Brain Nerve. 2015. PMID: 25846594 Review. Japanese.
-
Magnetoencephalography Signal Processing, Forward Modeling, Magnetoencephalography Inverse Source Imaging, and Coherence Analysis.Neuroimaging Clin N Am. 2020 May;30(2):125-143. doi: 10.1016/j.nic.2020.02.001. Neuroimaging Clin N Am. 2020. PMID: 32336402 Review.
Cited by
-
A physiologically motivated sparse, compact, and smooth (SCS) approach to EEG source localization.Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:1546-9. doi: 10.1109/EMBC.2012.6346237. Annu Int Conf IEEE Eng Med Biol Soc. 2012. PMID: 23366198 Free PMC article.
-
Evaluation of cortical current density imaging methods using intracranial electrocorticograms and functional MRI.Neuroimage. 2007 Apr 1;35(2):598-608. doi: 10.1016/j.neuroimage.2006.12.026. Epub 2006 Dec 30. Neuroimage. 2007. PMID: 17303438 Free PMC article.
-
Abnormal neural oscillations in clinical high risk for psychosis: a magnetoencephalography method study.Gen Psychiatr. 2022 Apr 28;35(2):e100712. doi: 10.1136/gpsych-2021-100712. eCollection 2022. Gen Psychiatr. 2022. PMID: 35572772 Free PMC article.
-
Voxel-wise resting-state MEG source magnitude imaging study reveals neurocircuitry abnormality in active-duty service members and veterans with PTSD.Neuroimage Clin. 2014 Aug 7;5:408-19. doi: 10.1016/j.nicl.2014.08.004. eCollection 2014. Neuroimage Clin. 2014. PMID: 25180160 Free PMC article.
-
Simultaneous head tissue conductivity and EEG source location estimation.Neuroimage. 2016 Jan 1;124(Pt A):168-180. doi: 10.1016/j.neuroimage.2015.08.032. Epub 2015 Aug 22. Neuroimage. 2016. PMID: 26302675 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources