Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Apr;21(1):5-10.
doi: 10.1007/s10103-006-0375-0. Epub 2006 Mar 17.

Closure of skin incisions by 980-nm diode laser welding

Affiliations
Comparative Study

Closure of skin incisions by 980-nm diode laser welding

Murat Gulsoy et al. Lasers Med Sci. 2006 Apr.

Abstract

A 980-nm diode laser is proposed to be an alternative welding laser in dermatology due to its optimal penetration in tissue. An in vivo predosimetry study was done to estimate the optimal laser energy delivery conditions (6 W, 400 ms). Next, in vivo experiments were comparatively performed to examine healing of wounds closed either with suture or laser welding. One-centimeter-long, full-thickness incisions were done on the dorsal side of Wistar rats. Wounds were surgically removed at 1, 4, 7, 14, and 21 days postoperatively. Macroscopic examinations showed that welding had minimal scarring and a fine quality healing. According to histological (hematoxylin and eosin staining) results, change of epidermal thickness and granulation tissue formation through 21 days of healing period showed similarities in both methods. Epidermal thickness of welded wounds decreased from 62.46+/-6.87 microm (first day) to 36.49+/-0.92 microm (21st day) and that of sutured wounds decreased from 62.94+/-13.53 microm (first day) to 37.88+/-7.41 microm (21st day). At day 14, epidermal thickness of sutured wounds (61.20+/-6.60 microm) were higher than welded wounds (49.69+/-6.31 microm) (p<0.05). Besides, granulation values were greater for the sutured wounds but the difference was statistically significant (p<0.05) only for the seventh day (197,190.29+/-.89,554.96 microm(2) for sutured wounds, 138,433.1+/-51,077.17 microm(2) for welded wounds). Those differences indicate a faster recovery with laser welding. It is concluded that tissue welding with a 980-nm diode laser can be a good candidate for tissue welding applications with accelerated and improved healing, but further investigations are in progress for clinical use.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Lasers Med Sci. 2001;16(4):260-6 - PubMed
    1. Lasers Surg Med. 2004;35(1):12-7 - PubMed
    1. Lasers Surg Med. 1997;21(3):278-86 - PubMed
    1. Lasers Med Sci. 2004;19(1):41-7 - PubMed
    1. Lasers Surg Med. 2000;27(1):55-65 - PubMed

Publication types

LinkOut - more resources