Case Reports
. 2006 Apr;90(4):417-9.
doi: 10.1136/bjo.2005.084905.

A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery

Affiliations
Case Reports

A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery

G Ainsworth et al. Br J Ophthalmol. 2006 Apr.

Abstract

Aim: To report a novel technique using amniotic membrane to cover exposed glaucoma tube shunts.

Methods: A consecutive series of three cases that underwent drainage tube shunt surgery with the Ahmed valve for intractable glaucoma. All three patients developed exposure of the tube secondary to necrosis of the overlying bovine pericardial patch and conjunctiva. Repair of the defect was carried out with a double layer of amniotic membrane, the inner one acting as a graft and the outer as a patch. Autologous serum was used to promote epithelial growth.

Results: Successful lasting closure of the conjunctival defect was achieved in all cases.

Conclusion: Erosion of the drainage tube following shunt surgery is a potentially serious problem. It can be successfully managed using a double layer of amniotic membrane.

PubMed Disclaimer

References

    1. Broadway D C, Iester M, Schulzer M.et al Survival analysis for success of Molteno tube implants. Br J Ophthalmol 200185689–695. - PMC - PubMed
    1. Ayyala R S, Zurakowski D, Smith J A.et al A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma. Ophthalmology 19981051968–1976. - PubMed
    1. Heuer D K, Lloyd M A, Abrams D A.et al Which is better? One or two? A randomized clinical trial of single‐plate versus double‐plate Molteno implantation for glaucomas in aphakia and pseudophakia. Ophthalmology 1992991512–1519. - PubMed
    1. Heuer D K, Budenz D, Coleman A. Aqueous shunt tube erosion. J Glaucoma 200110493–496. - PubMed
    1. Huang M C, Netland P A, Coleman A L.et al Intermediate‐term clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol 199912727–33. - PubMed