[Diagnostic value of multi-slice spiral CT three dimensional reconstruction in maxillofacial diseases]
- PMID: 16548181
[Diagnostic value of multi-slice spiral CT three dimensional reconstruction in maxillofacial diseases]
Abstract
Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) three dimensional (3D) reconstruction for maxillofacial diseases.
Methods: Sixty patients with maxillofacial diseases underwent the scanning of MSCT with 3D reconstruction. Among them, 34 patients with maxillofacial fracture, 10 patients with maxillofacial tumors and tumor-like diseases, and 16 patients with congenital deformities. The MSCT scanned with slice thickness of 2 mm. The methods of 3D reconstruction included multi-planar reconstruction (MPR), shaded surface display (SSD), and volume rendering (VR). The results were compared with what was observed during operations.
Results: Totally 36 cases of maxillofacial fracture were shown by 2D or 3D imaging and were validated by the observations during operation. The MSCT with 3D reconstruction imaging was significantly superior to 2D axial imaging in maxillofacial fracture. Three dimensional imaging could clearly show the spacial anatomy of facial, fragment displacement, and tracing fracture lines. However, 2D imaging had better effectiveness than 3D imaging in observing deep structure and fine fracture. In maxillofacial tumors and tumor-like diseases, 3D imaging was significantly superior to 2D axial imaging in showing the tumor shape and spacial relationships between tumors and surrounding structures. Two dimensional imaging and MPR imaging were excellent to reveal internal structure and pathological changes of tumors. 2D imaging and MPR imaging also achieved better results in showing tumors extended to soft tissues. In maxillofacial congenital deformities, 3D imaging were superior than 2D imaging.
Conclusion: 3D imaging has an important value in the diagnosis and clinical assessment of maxillofacial fracture, tumor-like diseases, and congenital deformities.
Similar articles
-
[Value of multi-slice spiral CT with three-dimensional reconstruction in the diagnosis of neoplastic lesions in the jawbones].Nan Fang Yi Ke Da Xue Xue Bao. 2008 Aug;28(9):1700-2, 1706. Nan Fang Yi Ke Da Xue Xue Bao. 2008. PMID: 18819902 Chinese.
-
[CT exam and 2D and 3D reconstructions in facial tumors diagnosis].Rev Med Chir Soc Med Nat Iasi. 2007 Oct-Dec;111(4):1056-64. Rev Med Chir Soc Med Nat Iasi. 2007. PMID: 18389805 Romanian.
-
Experimental comparative study of Two-dimensional and Three-dimensional CT reconstruction in detecting maxillofacial fractures at Mzuzu Central Hospital, Malawi.Malawi Med J. 2025 Feb 4;36(5):303-307. doi: 10.4314/mmj.v36i5.2. eCollection 2025 Feb. Malawi Med J. 2025. PMID: 40018017 Free PMC article.
-
[The three-dimensional spiral scanner and volume rendering technique: importance in craniofacial traumatology and reconstructive surgery].Rev Stomatol Chir Maxillofac. 2002 Sep;103(4):233-8. Rev Stomatol Chir Maxillofac. 2002. PMID: 12451333 Review. French.
-
CT of pelvic fractures.Eur J Radiol. 2004 Apr;50(1):96-105. doi: 10.1016/j.ejrad.2003.11.019. Eur J Radiol. 2004. PMID: 15093240 Review.