Perioperative and clinical-angiographic late outcome of total arterial myocardial revascularization according to different composite original graft techniques
- PMID: 16550306
- DOI: 10.1007/s00380-005-0856-2
Perioperative and clinical-angiographic late outcome of total arterial myocardial revascularization according to different composite original graft techniques
Abstract
Total arterial myocardial revascularization (TAMR) is advisable because of the excellent long-term patency of arterial conduits. We present early and midterm outcomes of five different surgical configurations for TAMR. Between January 1998 and May 2004, 112 patients (aged 56.5 +/- 4.5 years, 20% female) with three-vessel disease underwent TAMR. The internal mammary arteries (IMAs) were harvested in a sketelonized fashion. The surgical techniques for TAMR consisted in Y or T composite grafts (n = 88, 78%) constructed between the in situ right IMA (RIMA) and the free left IMA (LIMA) graft (n = 58) or the radial artery (n = 30) (RA) in three different configurations. The other techniques consisted in T- and inverted T-graft (n = 24, 22%) constructed between the RA conduit and the free LIMA graft in two different configurations. The mean follow-up time was 40 +/- 23 months. Postoperative angiographic control was performed in 76/111 (70%) patients. Overall, 472 arterial anastomoses (average 4.2 per patient) were performed. One (0.9%) patient, undergoing the inverted T-graft technique, died on postoperative day 2. Another patient (0.9%), undergoing the lambda-graft technique using both IMAs and RA, suffered a new myocardial infarction probably due to RA conduit vasospasm. One week after surgery, after the transthoracic echocardiographic Doppler with adenosine provocative test, the coronary flow reserve (CFR) at the LIMA and RIMA main stems were 2 +/- 0.4 and 2.4 +/- 0.3, respectively. At 12-month follow-up, after adenosine provocative test, the CFRs at the LIMA and RIMA stems were significantly higher than the values at 1 week after surgery within the same group; (LIMA)CFR (1 week) 2.4 +/- 0.3 (12 months) vs 2 +/- 04 (1 week), P = 0.002; (RIMA)CFR 2.58 +/- 0.4 vs 2.4 +/- 0.3, P = 0.001. The CFR at the RIMA main stem was higher in all measurements within the same group than in the LIMA main stem, but not significantly. In one patient undergoing the lambda-graft technique using both IMAs, the RIMA was found to have a string sign. Postoperative angiography in 50 patients showed that the patency rate for the LIMA was 100%, for the RIMA 97.3%, and for the RA 96.7%. Angiography at 3-year follow-up in 76 patients documented excellent patency rates of the LIMA (97.4%), RIMA (95%), and RA (87%). Survival at 7 years was 92.5%, event-free survival 89.3%, and freedom from angina 94%. Total arterial myocardial revascularization using different surgical configurations is safe and effective. The use of composite arterial grafts provides excellent clinical and angiographic results, with a low rate of angina recurrence and late cardiac events. These configurations allow for complete arterial revascularization.
Similar articles
-
Total arterial myocardial revascularization using new composite graft techniques for internal mammary and/or radial arteries conduits.J Card Surg. 1999 Nov-Dec;14(6):408-16. J Card Surg. 1999. PMID: 11021365
-
Off-pump total arterial myocardial revascularization according to the right Y-graft configuration.J Card Surg. 2003 Jan-Feb;18(1):8-16. doi: 10.1046/j.1540-8191.2003.01903.x. J Card Surg. 2003. PMID: 12696760
-
Lambda graft with the radial artery or free left internal mammary artery anastomosed to the right internal mammary artery: flow dynamics.Ann Thorac Surg. 2001 Oct;72(4):1275-81. doi: 10.1016/s0003-4975(01)02834-x. Ann Thorac Surg. 2001. PMID: 11603448
-
Angiographic outcomes of radial artery versus saphenous vein in coronary artery bypass graft surgery: a meta-analysis of randomized controlled trials.J Thorac Cardiovasc Surg. 2013 Aug;146(2):255-61. doi: 10.1016/j.jtcvs.2012.07.014. Epub 2012 Aug 4. J Thorac Cardiovasc Surg. 2013. PMID: 22871565 Review.
-
[Coronary bypass with arteries].Z Kardiol. 1991;80 Suppl 9:79-82. Z Kardiol. 1991. PMID: 1686697 Review. German.
Cited by
-
Long-term results of robotic-assisted coronary artery bypass grafting with composite arterial grafts for multiple coronary anastomoses: 10-year experience.J Robot Surg. 2023 Feb;17(1):63-71. doi: 10.1007/s11701-022-01391-z. Epub 2022 Mar 22. J Robot Surg. 2023. PMID: 35316487
-
Intraoperative behavior of arterial grafts in the elderly and the young: a flowmetric systematic analysis.Heart Vessels. 2008 Sep;23(5):316-24. doi: 10.1007/s00380-008-1055-8. Epub 2008 Sep 20. Heart Vessels. 2008. PMID: 18810580
-
Radial artery achieves better flowmetric results than saphenous vein in the elderly.Heart Vessels. 2009 Mar;24(2):108-15. doi: 10.1007/s00380-008-1095-0. Epub 2009 Apr 1. Heart Vessels. 2009. PMID: 19337794
-
Infiltration of CD68+ cells correlates positively with matrix metalloproteinase 2 expression in the arteries used as aortocoronary bypass grafts. Possible clinical implications.Cardiol J. 2020;27(6):817-824. doi: 10.5603/CJ.a2019.0087. Epub 2019 Sep 6. Cardiol J. 2020. PMID: 31489609 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources