Measuring intraocular pressure-adjustments for corneal thickness and new technologies
- PMID: 16552245
- DOI: 10.1097/01.icu.0000193093.05927.a1
Measuring intraocular pressure-adjustments for corneal thickness and new technologies
Abstract
Purpose of review: Central corneal thickness has become an important biometric factor and is an essential part of the evaluation of glaucoma. Goldmann applanation tonometry is the most widely used method of measuring intraocular pressure, but it is well known that corneal parameters affect the accuracy of this instrument. Intraocular pressure reduction is currently the only treatment available for decreasing the risk of glaucoma progression, so it is important to have an accurate reading of the true intraocular pressure.
Recent findings: New tonometers such as the dynamic contour tonometer and the Proview tonometer do not appear to be influenced by central corneal thickness. The ocular response analyzer provides a new measure of corneal biomechanics called corneal hysteresis. Rebound tonometry has been used in animal models of glaucoma, but has recently been compared to Goldmann applanation tonometry in humans. All of these technologies are presented in this review and the influence of corneal thickness on their accuracy is examined.
Summary: Confronted with the expanding evidence that central corneal thickness is an important ocular parameter that should be measured in clinical practice, eye-care professionals understandably wonder how to best obtain the measurements and what to do with the information. There is wide disagreement among investigators as to if there is an adequately validated 'correction algorithm'; without a validated algorithm, the argument goes, clinicians cannot use the data. These newer technologies may allow clinicians to be able to accurately determine the true intraocular pressure without having to rely on a correction algorithm.
Similar articles
-
New ways to measure intraocular pressure.Curr Opin Ophthalmol. 2008 Mar;19(2):122-6. doi: 10.1097/ICU.0b013e3282f391ae. Curr Opin Ophthalmol. 2008. PMID: 18301285 Review.
-
Assessment of true intraocular pressure: the gap between theory and practical data.Surv Ophthalmol. 2008 May-Jun;53(3):203-18. doi: 10.1016/j.survophthal.2008.02.005. Surv Ophthalmol. 2008. PMID: 18501267 Review.
-
Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, ocular response analyzer, and Goldmann tonometry in glaucomatous eyes.J Glaucoma. 2008 Aug;17(5):361-5. doi: 10.1097/IJG.0b013e31815c3ad3. J Glaucoma. 2008. PMID: 18703945
-
[Clinical evaluation of the ICare tonometer in measuring intraocular pressure].Klin Oczna. 2010;112(7-9):217-20. Klin Oczna. 2010. PMID: 21121124 Polish.
-
[Corneal pachymetry and intraocular pressure].Klin Monbl Augenheilkd. 2005 Jul;222(7):558-67. doi: 10.1055/s-2005-858113. Klin Monbl Augenheilkd. 2005. PMID: 16034723 Review. German.
Cited by
-
Comparison of Goldmann and Pascal tonometry in relation to corneal hysteresis and central corneal thickness in nonglaucomatous eyes.Clin Ophthalmol. 2011;5:1071-7. doi: 10.2147/OPTH.S23086. Epub 2011 Aug 3. Clin Ophthalmol. 2011. PMID: 21847339 Free PMC article.
-
Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer.Clin Ophthalmol. 2016 May 11;10:829-34. doi: 10.2147/OPTH.S106836. eCollection 2016. Clin Ophthalmol. 2016. PMID: 27274187 Free PMC article.
-
Corneal Biomechanics Determination in Healthy Myopic Subjects.J Ophthalmol. 2016;2016:2793516. doi: 10.1155/2016/2793516. Epub 2016 Jul 21. J Ophthalmol. 2016. PMID: 27525109 Free PMC article.
-
Intraocular pressure after Descemet's stripping and non-Descemet's stripping automated endothelial keratoplasty.Jpn J Ophthalmol. 2011 Mar;55(2):98-102. doi: 10.1007/s10384-010-0916-8. Epub 2011 Mar 13. Jpn J Ophthalmol. 2011. PMID: 21400052
-
Central corneal thickness in black Cameroonian ocular hypertensive and glaucomatous subjects.Clin Ophthalmol. 2010 Nov 24;4:1371-7. doi: 10.2147/OPTH.S14951. Clin Ophthalmol. 2010. PMID: 21179220 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials