Airborne dust particle counting techniques
- PMID: 16565805
- DOI: 10.1007/s10661-006-3264-x
Airborne dust particle counting techniques
Abstract
The paper briefly describes an electro-optical system for counting of dust particles, which is based on the scattering phenomena. Utilizing the scattering of light by various size particles present in the environment, various particle counting techniques have been developed in order to measure the scattered intensity of light. Light scatters in all directions but much more in the so-called near forward direction 17( composite function) off axis, at 163( composite function) from the light source in the visible range. On the basis of two techniques, the right angle and forward angle scattering, opto-mechanical systems have been developed which measure scattered intensity and particulate matter. The forward scattering Nephelometer is more sensitive and therefore is more suitable for pollution monitoring than the right angle scattering Nephelometer. Whereas the right angle scattering Nephelometer has the utility in extremely low concentration in ppb level owing to the excellent light trap efficiency in comparison to forward scattering Nephelometer. In this paper measurement techniques and measurement results associated with design and development of a real time particle analyser are also discussed.
Similar articles
-
New measurement principle and basic performance of high-sensitivity turbidimeter with two optical systems in series.Water Res. 2006 Feb;40(4):683-91. doi: 10.1016/j.watres.2005.11.032. Water Res. 2006. PMID: 16476466
-
Use of optical scatter sensors for measurement of visibility.J Environ Monit. 2005 Jun;7(6):608-11. doi: 10.1039/b414327b. Epub 2005 Apr 27. J Environ Monit. 2005. PMID: 15931423
-
Evaluation of the recursive model approach for estimating particulate matter infiltration efficiencies using continuous light scattering data.J Expo Sci Environ Epidemiol. 2007 Aug;17(5):468-77. doi: 10.1038/sj.jes.7500539. Epub 2006 Nov 15. J Expo Sci Environ Epidemiol. 2007. PMID: 17108894
-
Advances in nephelometry through the Ecotech Aurora nephelometer.ScientificWorldJournal. 2011;11:2530-5. doi: 10.1100/2011/310769. Epub 2011 Dec 28. ScientificWorldJournal. 2011. PMID: 22235183 Free PMC article. Review.
-
Light scattering measurement in an arc lamp-based flow cytometer.Cytometry. 1990;11(2):223-30. doi: 10.1002/cyto.990110202. Cytometry. 1990. PMID: 2180652 Review.
Cited by
-
Development and application of a method to classify airborne pollen taxa concentration using light scattering data.Sci Rep. 2021 Nov 16;11(1):22371. doi: 10.1038/s41598-021-01919-7. Sci Rep. 2021. PMID: 34785742 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources