Determination of furosemide in plasma and urine using monolithic silica rod liquid chromatography
- PMID: 16569489
- DOI: 10.1016/j.jpba.2006.02.025
Determination of furosemide in plasma and urine using monolithic silica rod liquid chromatography
Abstract
In the present study we developed a fast and reliable HPLC assay for the determination of the loop diuretic furosemide in plasma and urine, using a Chromolith RP 18e (100 mm x 4.6 mm) monolithic silica rod HPLC column. After liquid-liquid extraction with diethylether plasma or urine samples were separated with a gradient consisting of solvent A (20% acetonitrile) and solvent B (80% acetonitrile), both in 0.25% acetic acid. The flow rate was 3.5 ml/min and the effluent was monitored by fluorescence with excitation at 230 nm and emission at 410 nm. The retention times for the internal standard (naproxen) and for furosemide were 2.1 and 3.7 min, respectively, and total run time was 8 min. The calibration curves were linear between 7.8 and 1000 ng/ml, and within-assay and between-assay coefficients of variation were <6.5% and <10%, respectively. The proposed assay for furosemide in plasma and urine using monolithic silica rod chromatography is fast, sensitive, and reliable, and, thus, well suited for pharmacokinetic studies.
Similar articles
-
Fast and reliable determination of the antifungal drug voriconazole in plasma using monolithic silica rod liquid chromatography.J Chromatogr B Analyt Technol Biomed Life Sci. 2006 Mar 7;832(2):313-6. doi: 10.1016/j.jchromb.2006.01.015. Epub 2006 Feb 20. J Chromatogr B Analyt Technol Biomed Life Sci. 2006. PMID: 16488671
-
[Quantitative determination of furosemide in serum and urine by high-performance liquid chromatography with electrochemical detector].Yao Xue Xue Bao. 1991;26(12):923-7. Yao Xue Xue Bao. 1991. PMID: 1823992 Chinese.
-
High-throughput liquid-chromatography method with fluorescence detection for reciprocal determination of furosemide or norfloxacin in human plasma.Biomed Chromatogr. 2007 Jan;21(1):40-7. doi: 10.1002/bmc.715. Biomed Chromatogr. 2007. PMID: 17080503
-
Co-administration of furosemide with albumin for overcoming diuretic resistance in patients with hypoalbuminemia: a meta-analysis.J Crit Care. 2014 Apr;29(2):253-9. doi: 10.1016/j.jcrc.2013.10.004. Epub 2013 Oct 22. J Crit Care. 2014. PMID: 24268626 Review.
-
Pre-dosing metolazone with loop diuretic combination regimens.Nephrol Nurs J. 2006 Jan-Feb;33(1):78-9. Nephrol Nurs J. 2006. PMID: 16538931 Review. No abstract available.
Cited by
-
Sublingual administration of furosemide: new application of an old drug.Br J Clin Pharmacol. 2007 Dec;64(6):804-9. doi: 10.1111/j.1365-2125.2007.03035.x. Epub 2007 Sep 13. Br J Clin Pharmacol. 2007. PMID: 17875188 Free PMC article.
-
Silica-Based Monolithic Columns as a Tool in HPLC-An Overview of Application in Analysis of Active Compounds in Biological Samples.Molecules. 2020 Jul 9;25(14):3149. doi: 10.3390/molecules25143149. Molecules. 2020. PMID: 32660127 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources