A new equal area method to calculate and represent physiologic, anatomical, and alveolar dead spaces
- PMID: 16571964
- DOI: 10.1097/00000542-200604000-00013
A new equal area method to calculate and represent physiologic, anatomical, and alveolar dead spaces
Abstract
Background: Physiologic dead space is usually estimated by the Bohr-Enghoff equation or the Fletcher method. Alveolar dead space is calculated as the difference between anatomical dead space estimated by the Fowler equal area method and physiologic dead space. This study introduces a graphical method that uses similar principles for measuring and displaying anatomical, physiologic, and alveolar dead spaces.
Methods: A new graphical equal area method for estimating physiologic dead space is derived. Physiologic dead spaces of 1,200 carbon dioxide expirograms obtained from 10 ventilated patients were calculated by the Bohr-Enghoff equation, the Fletcher area method, and the new graphical equal area method and were compared by Bland-Altman analysis. Dead space was varied by varying tidal volume, end-expiratory pressure, inspiratory-to-expiratory ratio, and inspiratory hold in each patient.
Results: The new graphical equal area method for calculating physiologic dead space is shown analytically to be identical to the Bohr-Enghoff calculation. The mean difference (limits of agreement) between the physiologic dead spaces calculated by the new equal area method and Bohr-Enghoff equation was -0.07 ml (-1.27 to 1.13 ml). The mean difference between new equal area method and the Fletcher area method was -0.09 ml (-1.52 to 1.34 ml).
Conclusions: The authors' equal area method for calculating, displaying, and visualizing physiologic dead space is easy to understand and yields the same results as the classic Bohr-Enghoff equation and Fletcher area method. All three dead spaces--physiologic, anatomical, and alveolar--together with their relations to expired volume, can be displayed conveniently on the x-axis of a carbon dioxide expirogram.
Similar articles
-
Effects of alveolar dead-space, shunt and V/Q distribution on respiratory dead-space measurements.Br J Anaesth. 2005 Oct;95(4):538-48. doi: 10.1093/bja/aei212. Epub 2005 Aug 26. Br J Anaesth. 2005. PMID: 16126784
-
Systematic errors and susceptibility to noise of four methods for calculating anatomical dead space from the CO2 expirogram.Br J Anaesth. 2007 Jun;98(6):828-34. doi: 10.1093/bja/aem090. Epub 2007 Apr 30. Br J Anaesth. 2007. PMID: 17470845
-
Estimating alveolar dead space from the arterial to end-tidal CO(2) gradient: a modeling analysis.Anesth Analg. 2003 Dec;97(6):1846-1851. doi: 10.1213/01.ANE.0000090316.46604.89. Anesth Analg. 2003. PMID: 14633572
-
Estimation of dead space fraction can be simplified in the acute respiratory distress syndrome.Crit Care. 2010;14(5):195. doi: 10.1186/cc9237. Epub 2010 Sep 9. Crit Care. 2010. PMID: 20840798 Free PMC article. Review.
-
Assessing dead space. A meaningful variable?Minerva Anestesiol. 2006 Jun;72(6):521-8. Minerva Anestesiol. 2006. PMID: 16682925 Review.
Cited by
-
Volumetric capnography: lessons from the past and current clinical applications.Crit Care. 2016 Jun 23;20(1):184. doi: 10.1186/s13054-016-1377-3. Crit Care. 2016. PMID: 27334879 Free PMC article. Review.
-
A mathematical model for the first derivative wave analysis of the volumetric capnogram from the perspective of erythrocyte motion profiles.Heliyon. 2019 Jun 12;5(6):e01824. doi: 10.1016/j.heliyon.2019.e01824. eCollection 2019 Jun. Heliyon. 2019. PMID: 31223667 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources