. 2006 Jun;33(6):709-15.
doi: 10.1007/s00259-006-0075-9. Epub 2006 Mar 30.

Feasibility of in vivo dual-energy myocardial SPECT for monitoring the distribution of transplanted cells in relation to the infarction site

Affiliations

Feasibility of in vivo dual-energy myocardial SPECT for monitoring the distribution of transplanted cells in relation to the infarction site

Nguyen Tran et al. Eur J Nucl Med Mol Imaging. 2006 Jun.

Abstract

Purpose: Cell therapy using bone marrow mesenchymal stem cells (BMSCs) shows promise in the treatment of myocardial infarction (MI) but accurate cell delivery within MI areas remains critical. In the present study, we tested the feasibility of in vivo pinhole SPECT imaging for monitoring the sites of intramyocardial implanted BMSCs in relation to targeted MI areas in rats.

Methods: BMSCs were labelled with (111)In-oxine and injected within the fibrotic areas of 3-month-old MI in ten rats. Two days later, dual (111)In/(99m)Tc-sestamibi pinhole SPECT was recorded for localisation of (111)In-BMSCs on a 15-segment left ventricular (LV) division. Additional (99m)Tc-sestamibi pinhole SPECT had been performed 1 month earlier and on the day before transplantation. In vitro counting on histological sections was used to validate the pinhole SPECT determination of (111)In-BMSC activity within LV segments.

Results: The underperfused MI area (segments with <70% uptake) was stable between the (99m)Tc-sestamibi SPECT study recorded at 1 month (4.6+/-1.9 segments) and at 1 day (4.7+/-2.3 segments) before transplantation. (111)In-BMSCs were detected by dual-energy SPECT in 56 segments: 33 (59%) were underperfused MI segments but 23 (41%) were not (14 adjacent and nine remote segments). Finally, (111)In-labelled BMSCs were not detected in 14 out of the 47 (30%) underperfused MI segments.

Conclusion: When BMSCs are injected within MI areas in rats, sites of early cell retention do not always match the targeted MI areas. The dual-energy pinhole SPECT technique may be used for monitoring the sites of early retention of implanted BMSCs and the data obtained may have critical importance when analysing the effects of cardiac cell therapy.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Nucl Med. 2005 May;46(5):816-22 - PubMed
    1. J Nucl Cardiol. 2005 Mar-Apr;12(2):229-30 - PubMed
    1. Nucl Med Commun. 2003 Nov;24(11):1149-54 - PubMed
    1. Comput Med Imaging Graph. 1999 Sep-Oct;23(5):277-84 - PubMed
    1. Eur J Nucl Med. 1990;17 (1-2):83-90 - PubMed

Publication types

MeSH terms

LinkOut - more resources