Residual indoor contamination from world trade center rubble fires as indicated by polycyclic aromatic hydrocarbon profiles
- PMID: 16572771
- DOI: 10.1021/es0517015
Residual indoor contamination from world trade center rubble fires as indicated by polycyclic aromatic hydrocarbon profiles
Abstract
The catastrophic destruction of the World Trade Center (WTC) on Sept. 11, 2001 (9/11) created an immense dust cloud followed by fires that emitted smoke and soot into the air of New York City (NYC) well into December. Outdoor pollutant levels in lower Manhattan returned to urban background levels after about 200 days as the fires were put out and the debris cleanup was completed. However, particulate matter (PM) from the original collapse and fires also penetrated into commercial and residential buildings. This has created public concern because WTC dust is thought to cause adverse pulmonary symptoms including "WTC cough" and reduced lung capacity. Additionally, some recent studies have suggested a possible link between exposure to WTC contamination and other adverse health effects. Distinguishing between normal urban pollutant infiltration and residual WTC dust remaining in interior spaces is difficult; efforts are underway to develop such discriminator methods. Some progress has been made in identifying WTC dust by the content of fibers believed to be associated with the initial building collapse. There are also contaminants created by the fires that burned for 100 days in the debris piles of the building rubble. Using WTC ambient air samples, we have developed indicators for fire related PM based on the relative amounts of specific particle bound polycyclic aromatic hydrocarbons (PAHs) and the mass fraction of PAHs per mass of PM. These two parameters are combined, and we show a graphical method for discriminating between fire sources and urban particulate sources as applied to samples of settled dusts. We found that our PAHs based discriminator method can distinguish fire source contributions to WTC related particulate matter and dusts. Other major building fires or large open burn events could have similar PAHs characteristics. We found that random samples collected approximately 3.5 years after the WTC event from occupied indoor spaces (primarily residential) in the New York area are not statistically distinguishable from contemporary city background.
Similar articles
-
Characterization of the dust/smoke aerosol that settled east of the World Trade Center (WTC) in lower Manhattan after the collapse of the WTC 11 September 2001.Environ Health Perspect. 2002 Jul;110(7):703-14. doi: 10.1289/ehp.02110703. Environ Health Perspect. 2002. PMID: 12117648 Free PMC article.
-
Persistent organic pollutants in dusts that settled indoors in lower Manhattan after September 11, 2001.J Expo Anal Environ Epidemiol. 2004 Mar;14(2):164-72. doi: 10.1038/sj.jea.7500310. J Expo Anal Environ Epidemiol. 2004. PMID: 15014547
-
Relative congener scaling of Polychlorinated dibenzo-p-dioxins and dibenzofurans to estimate building fire contributions in air, surface wipes, and dust samples.Environ Sci Technol. 2007 Nov 1;41(21):7286-93. doi: 10.1021/es070714a. Environ Sci Technol. 2007. PMID: 18044501
-
Physical characteristics and health effects of aerosols from collapsed buildings.J Aerosol Med. 2006 Spring;19(1):84-91. doi: 10.1089/jam.2006.19.84. J Aerosol Med. 2006. PMID: 16551219 Review.
-
Health and environmental consequences of the world trade center disaster.Environ Health Perspect. 2004 May;112(6):731-9. doi: 10.1289/ehp.6702. Environ Health Perspect. 2004. PMID: 15121517 Free PMC article. Review.
Cited by
-
Blood-borne biomarkers and bioindicators for linking exposure to health effects in environmental health science.J Toxicol Environ Health B Crit Rev. 2016;19(8):380-409. doi: 10.1080/10937404.2016.1215772. Epub 2016 Oct 19. J Toxicol Environ Health B Crit Rev. 2016. PMID: 27759495 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical