Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2006 Apr;131(4):785-91.
doi: 10.1016/j.jtcvs.2005.11.031.

Flow study of an extracardiac connection with persistent left superior vena cava

Affiliations
Free article
Case Reports

Flow study of an extracardiac connection with persistent left superior vena cava

Diane A de Zélicourt et al. J Thorac Cardiovasc Surg. 2006 Apr.
Free article

Abstract

Background: Numerous studies have sought to optimize the design of total cavopulmonary connections with a single superior vena cava. This study was directed to the 2% to 4.5% of the population with dual superior venae cavae, investigating the flow fields associated with such total cavopulmonary connection anatomies. Additionally, it demonstrates the potential use of computational designs and simulations as surgical planning tools.

Methods: A 3-dimensional model of a total cavopulmonary connection with bilateral superior venae cavae was reconstructed from a patient's magnetic resonance images and investigated experimentally and numerically to assess the power losses and flow structures within the connection. On the basis of these results, a virtual operation was performed in the computer to improve the original connection design. The modified anatomy was studied numerically.

Results: Because of a smooth connection with an extracardiac conduit and no major dimension mismatch between the baffle and the connecting vessels, the original anatomy yielded smooth flow fields, low power losses, and few disturbances. However, a large offset between the inferior vena cava and the left superior vena cava resulted in flow stasis and unbalanced hepatic flow distribution. Shifting the inferior vena cava and positioning it between the 2 superior venae cavae resulted in a 7% decrease in power losses and eliminated the associated flow stasis regions in the main pulmonary artery segment.

Conclusions: This study demonstrates the potential use of computer-aided design and numeric simulations for surgical planning. It shows that locating the inferior vena cava between the superior venae cavae may lead to better-balanced lung perfusion. This may require suturing the right and left superior venae cavae closer to each other during the hemi-Fontan or Glenn stage.

PubMed Disclaimer

Publication types

LinkOut - more resources