Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2006 Apr 18;113(15):1824-31.
doi: 10.1161/CIRCULATIONAHA.105.601898. Epub 2006 Apr 10.

A tailored approach to catheter ablation of paroxysmal atrial fibrillation

Affiliations
Clinical Trial

A tailored approach to catheter ablation of paroxysmal atrial fibrillation

Hakan Oral et al. Circulation. .

Abstract

Background: Because the genesis of atrial fibrillation (AF) is multifactorial and variable, an ablation strategy that involves pulmonary vein isolation and/or a particular set of ablation lines may not be equally effective or efficient in all patients with AF. A tailored strategy that targets initiators and drivers of AF is a possible alternative to a standardized lesion set.

Methods and results: Catheter ablation was performed in 153 consecutive patients (mean age, 56+/-11 years) with symptomatic paroxysmal AF with the use of an 8-mm tip radiofrequency ablation catheter. The esophagus was visualized with barium. The pulmonary veins and left atrium were mapped during spontaneous or induced AF. Arrhythmogenic pulmonary veins were isolated or encircled. If AF was still present or inducible, complex electrograms in the left atrium, coronary sinus, and superior vena cava were targeted for ablation. The end point of ablation was absence of frequent atrial ectopy and spontaneous AF during isoproterenol infusion and noninducibility of AF. Routine energy applications near the esophagus were avoided. During follow-up, left atrial flutter developed in 19% of patients and was still present in 10% at >12 weeks of follow-up. A repeat ablation procedure was performed in 18% of patients. During a mean follow-up of 11+/-4 months, 77% of patients were free from AF and/or atrial flutter without antiarrhythmic drug therapy. Pericardial tamponade or transient neurological events occurred in 2% of procedures.

Conclusions: A tailored ablation strategy that only targets triggers and drivers of AF is feasible and eliminates paroxysmal AF in approximately 80% of patients.

PubMed Disclaimer

Comment in

Publication types