Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Oct;16(10):2265-74.
doi: 10.1007/s00330-006-0210-9. Epub 2006 Apr 11.

Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver: an ex vivo study

Affiliations

Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver: an ex vivo study

Olivier Seror et al. Eur Radiol. 2006 Oct.

Abstract

We evaluated the feasibility and accuracy of real-time magnetic resonance (MR) thermometry for monitoring radiofrequency (RF) ablation in the liver. Continuous MR temperature mapping was used to monitor bipolar RF ablations performed in ex vivo livers with and without flow using two parallel electrodes. Macroscopic inspection of ablation zones was compared with thermal dose maps (TDm) and T1-weighted inversion recovery turbo spin echo (IR-TSE) images for their size and shape and the influence of flow. Pearson's correlation (r), Bland and Altman tests and kappa (chiK) tests were performed. The mean differences in ablation zone size between macroscopic and TDm and IR-TSE measurements were +4 mm and -2 mm, respectively. TDm was well correlated with macroscopy (r=0.77 versus r=0.44 for IR-TSE). TDm was found to be more precise for shape recognition (chiK=0.73 versus chiK=0.55 for IR-TSE) and for detection of an intact ring of liver due to the cooling effect of flow which was impossible with IR-TSE. Simultaneous monitoring of RF ablation by MR thermometry is feasible and reliable for predicting the shape of ablation zones and the impact of the heat-sink effect of flow. Further studies are needed to confirm these results in vivo.

PubMed Disclaimer

References

    1. J Magn Reson Imaging. 1998 Jan-Feb;8(1):110-4 - PubMed
    1. J Vasc Interv Radiol. 2003 Oct;14(10):1267-74 - PubMed
    1. AJR Am J Roentgenol. 2002 May;178(5):1147-51 - PubMed
    1. Radiology. 1998 Dec;209(3):761-7 - PubMed
    1. Eur J Radiol. 2005 Jun;54(3):408-17 - PubMed

LinkOut - more resources