Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods
- PMID: 16609861
- DOI: 10.1007/s00330-006-0222-5
Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods
Abstract
This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method.
Similar articles
-
Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction.Int J Cardiovasc Imaging. 2015 Dec;31 Suppl 2:223-32. doi: 10.1007/s10554-015-0751-6. Epub 2015 Aug 29. Int J Cardiovasc Imaging. 2015. PMID: 26319216
-
Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease.Acta Radiol. 2012 Apr 1;53(3):270-7. doi: 10.1258/ar.2011.110247. Epub 2012 Feb 8. Acta Radiol. 2012. PMID: 22319133
-
[Assessment of global and regional left ventricular function with a 16-slice spiral-CT using two different software tools for quantitative functional analysis and qualitative evaluation of wall motion changes in comparison with magnetic resonance imaging].Rofo. 2004 Dec;176(12):1786-93. doi: 10.1055/s-2004-813730. Rofo. 2004. PMID: 15573290 German.
-
Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.Eur J Nucl Med Mol Imaging. 2004 Apr;31(4):482-90. doi: 10.1007/s00259-003-1411-y. Epub 2004 Jan 14. Eur J Nucl Med Mol Imaging. 2004. PMID: 14722679 Clinical Trial.
-
[Left ventricular functional parameters using ECG-gated multidetector spiral CT in comparison with invasive ventriculography].Rofo. 2003 Oct;175(10):1349-54. doi: 10.1055/s-2003-42892. Rofo. 2003. PMID: 14556103 German.
Cited by
-
Evaluation of left atrial volumes using multidetector computed tomography: comparison with echocardiography.Korean J Radiol. 2010 May-Jun;11(3):286-94. doi: 10.3348/kjr.2010.11.3.286. Epub 2010 Apr 30. Korean J Radiol. 2010. PMID: 20461182 Free PMC article.
-
Stereological estimation of left-ventricular volumetric and functional parameters from multidetector-row computed tomography data.Eur Radiol. 2008 Jul;18(7):1338-49. doi: 10.1007/s00330-008-0901-5. Epub 2008 Mar 20. Eur Radiol. 2008. PMID: 18351349
-
Integrated teaching of anatomy and radiology using three-dimensional image post-processing.Eur Radiol. 2009 Dec;19(12):2870-7. doi: 10.1007/s00330-009-1507-2. Eur Radiol. 2009. PMID: 19597821
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical