Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

Affiliations
Comparative Study

Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

M Montaudon et al. Eur Radiol. 2006 Oct.

Abstract

This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Radiat Med. 2003 Mar-Apr;21(2):62-7 - PubMed
    1. Radiology. 2003 Dec;229(3):749-56 - PubMed
    1. AJR Am J Roentgenol. 2005 Mar;184(3):765-73 - PubMed
    1. Radiology. 2004 Feb;230(2):403-10 - PubMed
    1. Int J Cardiovasc Imaging. 2003 Feb;19(1):73-83 - PubMed

Publication types