Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques
- PMID: 16612304
- DOI: 10.1097/01.ta.0000195462.53525.0c
Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques
Abstract
Background: Locking plates are an alternative to conventional compression plate fixation for diaphyseal fractures. The objective of this study was to compare the stability of various plating with locked screw constructs to conventional nonlocked screws for fixation of a comminuted diaphyseal fracture model using a uniform, synthetic ulna. Locked screw construct variables were the use of unicortical or bicortical screws, and increasing bone to plate distance.
Methods: This biomechanical study compared various construct groups after cyclic axial loading and three-point bending. Results were analyzed via one-way analysis of variance. Displacements after cyclical axial loading and number of cycles to failure in cyclic bending were used to assess construct stability.
Results: The constructs fixed by plates with bicortical locked screws withstood significantly more cycles to failure than the other constructs (p < 0.001). Significantly less displacement occurred after axial loading with bicortical locked screws than with bicortical nonlocked screws. Increased distance of the plate from the bone surface, and use of unicortical locked screws led to early failure with cyclic loading for constructs with locked screws.
Conclusions: These results support the use of plating with bicortical locked screws as an alternative to conventional plating for comminuted diaphyseal fractures in osteoporotic bone. Bicortical locked screws with minimal displacement from the bone surface provide the most stable construct in the tested synthetic comminuted diaphyseal fracture model. The results of this study suggest use of plates with unicortical screws for the described fracture is not recommended.
Similar articles
-
Biomechanical evaluation of locking plate radial shaft fixation: unicortical locking fixation versus mixed bicortical and unicortical fixation in a sawbone model.J Hand Surg Am. 2007 Sep;32(7):971-5. doi: 10.1016/j.jhsa.2007.05.019. J Hand Surg Am. 2007. PMID: 17826548
-
Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis.J Trauma. 2010 Aug;69(2):411-7. doi: 10.1097/TA.0b013e3181ec9417. J Trauma. 2010. PMID: 20699751
-
Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study.J Hand Surg Am. 2005 Jul;30(4):756-63. doi: 10.1016/j.jhsa.2005.04.017. J Hand Surg Am. 2005. PMID: 16039369
-
Has locked plating completely replaced conventional plating?Am J Orthop (Belle Mead NJ). 2004 Sep;33(9):439-46. Am J Orthop (Belle Mead NJ). 2004. PMID: 15509108 Review.
-
Biomechanics of locked plates and screws.J Orthop Trauma. 2004 Sep;18(8):488-93. doi: 10.1097/00005131-200409000-00003. J Orthop Trauma. 2004. PMID: 15475843
Cited by
-
Analysis of risk factors for revision in distal femoral fractures treated with lateral locking plate: a retrospective study in Chinese patients.J Orthop Surg Res. 2020 Aug 12;15(1):318. doi: 10.1186/s13018-020-01850-z. J Orthop Surg Res. 2020. PMID: 32787946 Free PMC article.
-
Optimal internal fixation of anatomically shaped synthetic bone grafts for massive segmental defects of long bones.Clin Biomech (Bristol). 2015 Dec;30(10):1114-8. doi: 10.1016/j.clinbiomech.2015.08.016. Epub 2015 Sep 2. Clin Biomech (Bristol). 2015. PMID: 26386637 Free PMC article.
-
In vitro analysis and in vivo assessment of fracture complications associated with use of locking plate constructs for stabilization of caprine tibial segmental defects.J Exp Orthop. 2023 Apr 3;10(1):38. doi: 10.1186/s40634-023-00598-9. J Exp Orthop. 2023. PMID: 37010659 Free PMC article.
-
Clinical Outcomes of Treatment Strategies for Postoperative Plate Fracture and In Situ Fracture of the Femoral Shaft.Biomed Res Int. 2022 Aug 26;2022:8145438. doi: 10.1155/2022/8145438. eCollection 2022. Biomed Res Int. 2022. Retraction in: Biomed Res Int. 2023 Jul 12;2023:9845478. doi: 10.1155/2023/9845478. PMID: 36060150 Free PMC article. Retracted.
-
Minimally invasive osteosynthesis of adult tibia fractures by means of rigid fixation with anatomic locked plates.Strategies Trauma Limb Reconstr. 2013 Aug;8(2):103-9. doi: 10.1007/s11751-013-0164-9. Epub 2013 Jul 24. Strategies Trauma Limb Reconstr. 2013. PMID: 23881464 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical