Accuracy of sonographic volume measurements of kidney transplant
- PMID: 16615053
- DOI: 10.1002/jcu.20212
Accuracy of sonographic volume measurements of kidney transplant
Abstract
Purpose: Sonographic measurement of renal volume is one of the parameters used in the diagnosis of renal transplant dysfunction and in follow-up of patients with renal transplant. The aim of this study was to compare the prolate ellipsoid formula with a new formula in calculating the volume of a transplanted kidney.
Methods: The renal volumes in 24 patients with a stable renal transplant were determined sonographically with the ellipsoid formula and via helical CT with the voxel-count method, which is the gold standard. A new formula that uses renal length and the cross-sectional area at the maximum transverse section has been evaluated in a small series of transplanted kidneys.
Results: Renal volume was underestimated with the sonographic ellipsoid formula and the new formula. The new formula yielded the lowest underestimation of the mean renal volume, and the measurements obtained with it were not significantly different from those obtained with CT.
Conclusions: The use of sonography is appropriate for accurate calculation of renal volume, and the new formula that uses only 2 ultrasound parameters best represents the volume of a renal transplant.
Copyright 2006 Wiley Periodicals, Inc.
Similar articles
-
Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging.Radiology. 1999 Jun;211(3):623-8. doi: 10.1148/radiology.211.3.r99jn19623. Radiology. 1999. PMID: 10352583
-
Kidney dimensions at sonography are correlated with glomerular filtration rate in renal transplant recipients and in kidney donors.Transplant Proc. 2007 Jul-Aug;39(6):1779-81. doi: 10.1016/j.transproceed.2007.05.003. Transplant Proc. 2007. PMID: 17692610
-
Estimation of feline renal volume using computed tomography and ultrasound.Vet Radiol Ultrasound. 2013 Mar-Apr;54(2):127-32. doi: 10.1111/vru.12007. Epub 2012 Dec 20. Vet Radiol Ultrasound. 2013. PMID: 23278991
-
Optimizing renal transplant Doppler ultrasound.Abdom Radiol (NY). 2018 Oct;43(10):2564-2573. doi: 10.1007/s00261-018-1731-9. Abdom Radiol (NY). 2018. PMID: 30121777 Review.
-
Measuring pituitary tumor volume: a comparison of the simplified and non-simplified ellipsoid equation with the 3D planimetric volume assessment.Pituitary. 2023 Aug;26(4):383-392. doi: 10.1007/s11102-023-01317-4. Epub 2023 Apr 28. Pituitary. 2023. PMID: 37115292 Review.
Cited by
-
Characteristics of intraoperative abnormal hemodynamics during resection of an intra-fourth ventricular tumor located on the dorsal medulla oblongata.Neurol Med Chir (Tokyo). 2013;53(10):655-62. doi: 10.2176/nmc.oa2012-0401. Epub 2013 Sep 27. Neurol Med Chir (Tokyo). 2013. PMID: 24077276 Free PMC article.
-
Timing urinary tract reconstruction in rats to avoid hydronephrosis and fibrosis in the transplanted fetal metanephros as assessed using imaging.PLoS One. 2021 Jan 15;16(1):e0231233. doi: 10.1371/journal.pone.0231233. eCollection 2021. PLoS One. 2021. PMID: 33449930 Free PMC article.
-
Semiautomatic three-dimensional ultrasound renal volume segmentation in pediatric hydronephrosis: interrater agreement and correlation to conventional hydronephrosis grading.Pediatr Radiol. 2025 May;55(6):1298-1307. doi: 10.1007/s00247-025-06249-8. Epub 2025 May 6. Pediatr Radiol. 2025. PMID: 40327095 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical