Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis
- PMID: 16615800
- DOI: 10.1021/ac052256z
Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis
Abstract
In this paper, the third generation of flow injection analysis, also named the lab-on-valve (LOV) approach, is proposed for the first time as a front end to high-performance liquid chromatography (HPLC) for on-line solid-phase extraction (SPE) sample processing by exploiting the bead injection (BI) concept. The proposed microanalytical system based on discontinuous programmable flow features automated packing (and withdrawal after single use) of a small amount of sorbent (<5 mg) into the microconduits of the flow network and quantitative elution of sorbed species into a narrow band (150 microL of 95% MeOH). The hyphenation of multisyringe flow injection analysis (MSFIA) with BI-LOV prior to HPLC analysis is utilized for on-line postextraction treatment to ensure chemical compatibility between the eluate medium and the initial HPLC gradient conditions. This circumvents the band-broadening effect commonly observed in conventional on-line SPE-based sample processors due to the low eluting strength of the mobile phase. The potential of the novel MSFI-BI-LOV hyphenation for on-line handling of complex environmental and biological samples prior to reversed-phase chromatographic separations was assessed for the expeditious determination of five acidic pharmaceutical residues (viz., ketoprofen, naproxen, bezafibrate, diclofenac, and ibuprofen) and one metabolite (viz., salicylic acid) in surface water, urban wastewater, and urine. To this end, the copolymeric divinylbenzene-co-n-vinylpyrrolidone beads (Oasis HLB) were utilized as renewable sorptive entities in the micromachined unit. The automated analytical method features relative recovery percentages of >88%, limits of detection within the range 0.02-0.67 ng mL(-1), and coefficients of variation <11% for the column renewable mode and gives rise to a drastic reduction in operation costs ( approximately 25-fold) as compared to on-line column switching systems.
Similar articles
-
On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach.J Chromatogr A. 2010 May 28;1217(22):3575-82. doi: 10.1016/j.chroma.2010.03.035. Epub 2010 Mar 27. J Chromatogr A. 2010. PMID: 20399441
-
Online hyphenation of multimodal microsolid phase extraction involving renewable molecularly imprinted and reversed-phase sorbents to liquid chromatography for automatic multiresidue assays.Anal Chem. 2010 Apr 1;82(7):3052-60. doi: 10.1021/ac100185s. Anal Chem. 2010. PMID: 20218575
-
Online coupling of bead injection lab-on-valve analysis to gas chromatography: application to the determination of trace levels of polychlorinated biphenyls in solid waste leachates.Anal Chem. 2009 Jun 15;81(12):4822-30. doi: 10.1021/ac900409u. Anal Chem. 2009. PMID: 19438246
-
Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.J Biochem Biophys Methods. 2007 Mar 10;70(2):263-73. doi: 10.1016/j.jbbm.2006.10.001. Epub 2006 Oct 10. J Biochem Biophys Methods. 2007. PMID: 17113152 Review.
-
An overview of sequential injection chromatography.Anal Chim Acta. 2007 Sep 26;600(1-2):129-35. doi: 10.1016/j.aca.2007.02.018. Epub 2007 Feb 20. Anal Chim Acta. 2007. PMID: 17903474 Review.
Cited by
-
Automatic analytical approach for the determination of 12 illicit drugs and nicotine metabolites in wastewater using on-line SPE-UHPLC-MS/MS.J Pharm Anal. 2021 Dec;11(6):739-745. doi: 10.1016/j.jpha.2021.01.002. Epub 2021 Jan 22. J Pharm Anal. 2021. PMID: 35028179 Free PMC article.
-
Flow Chemistry in Contemporary Chemical Sciences: A Real Variety of Its Applications.Molecules. 2020 Mar 21;25(6):1434. doi: 10.3390/molecules25061434. Molecules. 2020. PMID: 32245225 Free PMC article. Review.
-
Lab-In-Syringe with Bead Injection Coupled Online to High-Performance Liquid Chromatography as Versatile Tool for Determination of Nonsteroidal Anti-Inflammatory Drugs in Surface Waters.Molecules. 2021 Sep 3;26(17):5358. doi: 10.3390/molecules26175358. Molecules. 2021. PMID: 34500791 Free PMC article.
-
Applicability of Internal Standardization with Yttrium to the Solid-phase Extraction of Trace Elements in Groundwater and Wastewater Using an Aminocarboxylic Acid-type Chelating Resin.Anal Sci. 2021 Aug 10;37(8):1147-1156. doi: 10.2116/analsci.20P387. Epub 2021 Jan 29. Anal Sci. 2021. PMID: 33518583
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous